Installing the torque arm

The tool torque should not exceed the specified torque range of each specific arm.

The angle of tool holder attachment, ω, is limited to 0° at SMC Posi 3 to achieve proper accuracy for positioning.

Mounting on a ceiling

  • Put the mounting point straight above, or as close as possible to, the point where the torque is applied.

  • Make sure that the fixation point can handle the weight and the torque of the chosen torque arm.

  • Attach the safety wire (see Spare Parts) to a second point that does not limit the working area.