Product Data

Operating torque range

from 20% to 100% of the capacity

Torque measurement accuracy
(within the operating torque range)

1%

Mechanical repeatability click

± 3%

Overload capacity

150 % of nominal capacity

Maximum angular speed

250 °/s

Angle measurement accuracy

± 3.6 ° / 360 ° (at 6 ° per second)

Temperature stability of torque measurement

+10 °C to +40 °C (10 °F to 104 °F)

Tightening results memory capacity

10000 (maximum)

Power supply

Rechargeable NiMH AA battery 1900mAh 1.2V