Tool Condition Test

A

Static Torque Transducer SRTT

B

STa6000

Test the maximum torque and pulse frequency

Set the filter frequency in STa6000 to 850 Hz.

Test the max torque and pulse frequency using a SRTT static torque transducer. Tightening time approximately 1 second.

Test Conditions

Temperature pulse unit: approximately 20° C.

In POWER FOCUS 6000, change Tool → Adjustment → Torque Adjustment Factor to 50%, prevents the tool from shutting off. Measure torque and pulse frequency rate clockwise in the SRTT for about 1 second. Check that the values meet the specified limits in table below.

A tool in good condition should achieve the following values:

Model

Pulse frequency

Max Torque CW static (minimum) (Nm)

ETP TBP/TBP-S 6

12-20 Hz

> 42 Nm

ETP TBP/TBP-S 6 (42)

10-18 Hz

>39 Nm

ETP TBP/TBP-S 8

11-20 Hz

> 64 Nm

ETP TBP/TBP-S 9

10-19 Hz

> 97 Nm

ETP TBP/TBP-S 13

8-15 Hz

> 181 Nm