Impulse Single-Step Rundown Stage Parameters

During rundown, the tool can use either speed mode, with a constant motor speed, or pulse mode. The selection is made depending on the encountered torque and the given torque limits within the configuration.

Parameter name

Condition

Description

Default value

Rundown speed

Selected by radio buttons.

Rundown speed can be selected between Max or Manual.

Max

Rundown speed

Rundown speed = manual

Specifies the tool speed during the rundown step.

0 rpm

Rundown time limits

Selected from a shortcut menu:

Off:Rundown time limits is turned off.

From Trigger: Rundown time limits is turned On. The system starts to monitor the time as soon as the tool trigger is pressed and reports if the time limits are violated.

From torque: Rundown time limits is turned On. The system starts to monitor the time from the specified torque value and reports if the time limits are violated.

Off

Rundown time monitoring torque

Rundown time limits = from torque

Torque value from where Rundown time limits monitor starts.

2.5 Nm

Time min

Rundown time limits = On

Minimum allowed time for rundown.

10ms

Time max

Rundown time limits = On

Maximum allowed time for rundown.

5000ms

Rundown pulse limits

Selected from a shortcut menu:

Off:Rundown pulse limits is turned off.

From Trigger: Rundown pulse limits is turned On. The system starts to monitor the pulses as soon as the tool trigger is pressed and reports if the pulse limits are violated.

From torque: Rundown pulse limits is turned On. The system starts to monitor the pulses from the specified torque value and reports if the pulse limits are violated.

Off

Rundown pulse monitoring torque

Rundown pulse limits = from torque

Torque value from where the Rundown pulse limits monitor starts.

2.5 Nm

Pulses min

Rundown pulse limits = On

Minimum number of pulses to reach the target.

2

Pulses max

Rundown pulse limits = On

Maximum number of pulses to reach the target.

50

Rundown complete torque

 

Defines the torque value for when snug is reached and rundown is completed.

5 Nm