Impulse Single-Step Start Stage Parameters

During the start stage, the tool rotates in a speed mode without any pulsing.

Parameter name

Description

Default Value

Soft start

Enables setting of the tool’s speed, angle and maximum torque to facilitate the bolt entering the thread.

Selected by radio buttons.

Off: Soft start is turned off.

On:Soft start is turned on.

Off

Speed

Defines the speed during the soft start.

300 rpm

Time

Defines the Soft start duration.

400 ms

Rehit detection

Early: Terminates the tightening immediately when an already tightened screw/bolt is detected. The tightening will be considered as NOK. Requires that Soft start is activated.

Complete: Even though an already tightened screw/bolt is detected, the tightening is not terminated until all tightening steps have been executed. The tightening will be considered as NOK. To make a rehit detection when Soft start is not activated, the Rehit detection Complete option must be selected. Rehit detection Complete will not terminate the tightening until all tightening steps have been executed. The tightening will be considered a rehit if the speed fails to reach half the rundown speed, a rehit error is then indicated.

Off: No rehit detection will be performed.

Combination Soft start = Off and Rehit = Early is not allowed.

Off

Use attachment tuning

Attachment tuning is selected by radio buttons.

No

Gear ratio

Socket rotation speed = Tool speed / gear ratio.

1.00

Efficiency tuning

For example 0.9 means 10% efficiency loss.

1.00