EM Stop Connector Configurations

The following EM Stop connector configurations are possible:

  • EM Stop entry configuration - single controller.

  • EM Stop entry configuration - multiple controllers.

  • EM Stop bypass configuration.

  • EM Stop loopback configuration.

EM Stop Entry Configuration - Single Controller

EM Stop button connector: Phoenix, 10-pin headers, 3.5 mm pitch

Use the following pin configuration:

Pin

Pin name

Use

1

EM_NC1

Connect a jumper between pin 1 and pin 2

2

EM_STOP+

See pin 1

3

EM_STOP+

Connect an emergency button between pin 3 and pin 4

4

24V_ISOL_EXT

See pin 3

5

EM_STOP-

Connect an emergency button between pin 5 and pin 6

6

GND

See pin 5

7

EM_BYPASS_STOP-

Do not use

8

EM_BYPASS_NC

Do not use

9

EM_RESET_IN

Connect a reset button between pin 9 and 10

10

EM_NC2

See pin 9

EM Stop Entry Configuration - Multiple Controllers

EM Stop button connector: Phoenix, 10-pin headers, 3.5 mm pitch

Use the following pin configuration:

Pin

Pin name

Use

1

EM_NC1

Connect a jumper between pin 1 and pin 2

2

EM_STOP+

See pin 1

3

EM_STOP+

Connect an emergency button between pin 3 and pin 4

4

24V_ISOL_EXT

See pin 3

5

EM_STOP-

Connect an emergency button between pin 5 and pin 6

6

GND

See pin 5

7

EM_BYPASS_STOP-

Do not use

8

EM_BYPASS_NC

Connect a reset button between pin 8 and 9

9

EM_RESET_IN

See pin 8

10

EM_NC2

Do not use

EM Stop Bypass Configuration

EM Stop I/O cable connector: Phoenix, 10-pin

Remove plug or use the following pin configuration:

Pin

Pin name

Use

1

EM_NC1

Do not use.

2

EM_STOP+

Do not use.

3

EM_STOP+

Do not use.

4

24V_ISOL_EXT

Do not use.

5

EM_STOP-

Do not use.

6

GND

Do not use.

7

EM_BYPASS_STOP-

Do not use.

8

EM_BYPASS_NC

Do not use.

9

EM_RESET_IN

Do not use.

10

EM_NC_2

Do not use.

EM Stop Loopback Configuration

EM Stop I/O cable connector: Phoenix, 10-pin

Use the following pin configuration:

Pin

Pin name

Use

1

EM_NC1

Do not use.

2

EM_STOP+

Do not use.

3

EM_STOP+

Do not use.

4

24V_ISOL_EXT

Do not use.

5

EM_STOP-

Do not use.

6

GND

Do not use.

7

EM_BYPASS_STOP-

Do not use.

8

EM_BYPASS_NC

Connect a jumper between pin 8 and 10.

9

EM_RESET_IN

Do not use.

10

EM_NC_2

See pin 8.