Target Angle Limits
With Target angle limits set, it is possible to monitor whether the nut is turned the desired angle during the tightening.
Parameter | Description | Default value |
---|---|---|
Angle limits | Choose the section of the tightening, in degrees, in which to monitor the angle.
| Off |
<From torque> | Torque value from where angle limits are set. |
|
<From torque> | Torque value from where angle limits are set. | 75% of Target Torque |
Angle min | Angle value for lower angle limit | 90° |
Angle max | Angle value for upper angle limit | 720° |
Time min | Minimum time (in milliseconds) for the step. Measured from the start of the step. | 10 ms For TurboTight: 0 ms |
Time max | Maximum time (in milliseconds) for the step. Measured from the start of the step. | 1000 ms For TurboTight: 40 ms |
Position 1-4 are valid if the target is torque. Position 5-6 are valid if the target is angle.
The parameter Measure angle at can have different values. The parameter is only available when angle monitoring is turned on for the tightening program used. By default the angle is measured at Max angle value. The possible values of the parameter are listed in the table below.
Name | Description |
---|---|
Value at peak torque | Measures the angle at the highest torque value. |
Max angle value | Measures the highest angle during tightening. |
Value at shutoff | Measures the last angle value before entering the break step. |