T+A – Tighten to Torque Plus Angle

Tools

ES

STR

SL

ST

SR

QST

STB

IXB

This step runs the tool until the target torque is reached. From this point it continues to run an additional target angle.

Parameter

Description

Target torque

The torque target. Must be > 0.

Target angle

The angle target. Must be > 0.

Speed ramp type

Hard, soft, or manual. Default: Hard. If you select Manual, the Speed ramp field opens.

Speed ramp

If Speed ramp type is Manual, this field opens. Default: 500 rpm/s.

Speed

Default: 60 rpm.

Brake

(Valid only for Power Focus 6000 StepSync, Power Focus 8 StepSync, and Flex).

If On the tool will be stopped when the target is reached.

If Off the program goes directly to the next step without stopping the tool.

Point and click on image to see more information: