T+A – Tighten to Torque Plus Angle
Tools |
---|
ES STR SL ST SR QST STB IXB |
This step runs the tool until the target torque is reached. From this point it continues to run an additional target angle.
Parameter | Description |
---|---|
Target torque | The torque target. Must be > 0. |
Target angle | The angle target. Must be > 0. |
Speed ramp type | Hard, soft, or manual. Default: Hard. If you select Manual, the Speed ramp field opens. |
Speed ramp | If Speed ramp type is Manual, this field opens. Default: 500 rpm/s. |
Speed | Default: 60 rpm. |
Brake (Valid only for Power Focus 6000 StepSync, Power Focus 8 StepSync, and Flex). | If On the tool will be stopped when the target is reached. If Off the program goes directly to the next step without stopping the tool. |
Point and click on image to see more information:
A | Target Torque |
B | Target Angle |