STwrench Tightening Step Parameters

The parameters shown in the tables are available if one of the STwrench strategies are used. There are several combinations of strategies. Some of the parameters are only available for certain strategies and may not be visible in other strategies.

Parameter rules are automatically checked. If a violation occurs, the error indicator is displayed beside the incorrect parameters. Select the error indicator to display more information about the error.

Switching between strategies can result in the error indicator being shown. This indicates that the chosen combination is invalid, and needs to be corrected.

For more information about the STwrench, see the STwrench User Guide (printed matter number 9836 4134 01).

Parameters in the STwrench tightening step

Parameter name

Condition

Description

Default value

Target

Select the target from the drop-down menu.
The parameter options are:

Torque, Angle, Torque or Angle.

Torque

Target Torque

 

Defines the target torque for tightening step.

0 Nm

Target Angle

Target = Angle

Defines the target angle for tightening step.

360°

Torque limits

Target = Torque

Selection made by a switch.

Auto or Manually position.

 

Torque min

Torque limits = Manual

Torque value for the lower limit

0 Nm

Torque max

Torque limits = Manual

Torque value for the upper limit

0 Nm

Angle limits

Target = Angle

Selected from a drop-down menu. The parameter options are:

Auto or Manually.

Angle values for max and min can be or selected

Angle limits

Target = Torque

Selected from a drop-down menu. The parameter options are:

Off: No angle limit monitoring.

From rundown complete: The monitoring window is set from when the Rundown complete torque is reached.

From torque: The monitoring window is set from when the specific torque value is reached.

Final angle monitoring torque

 

Torque value from when the angle limits are monitored

18.75 Nm

Angle min

Angle limits = on or manually

Angle value lower limit

324°

Angle max

Angle limits = on or manually

Angle value upper limit

396°

Angle search limit

Angle limits = manually

Measure torque at

 

Selected from a drop-down menu. The parameter options are:

Max torque value

Value at peak angle

 

NOK on final less than target

 

Selection made by a switch.

On or Off position.

Off

Change bolt limit

 

50 Nm

Parameters in the STwrench tightening step if the strategy is Wrench - Production, and PVT compensate with snug

Parameter name

Condition

Description

Default value

Torque compensation point

Torque compensation = On

PCT distance

Torque compensation = On

360°

PVT interval

Torque compensation = On

180°

Delay monitoring

Torque compensation = On

Torque min

Torque compensation = On

Torque value for the lower limit

1 Nm

Torque max

Torque compensation = On

Torque value for the upper limit

20 Nm

Compensation value

Torque compensation = On

Selected from a drop-down menu. The parameter options are:

Average torque

Peak torque