Maintenance
Go to Integrated Controller Tool in the home and select Tool in the left pane.
Expand the Maintenance field. The following information is displayed:
Parameter
Description
Is the transducer overloaded?
Yes - the transducer has been overloaded.
No - the transducer has not been overloaded.
Highest torque value
Highest torque output measured by the transducer.
Highest torque date
Date and time when the highest torque output was measured by the transducer.
Number of successful tightenings
Number of completed tightenings.
Angle correction
Angle correction coefficient due to the wrench bending.
Angle correction coefficient for the smartHEAD. Note that this coefficient is related to the torsion of the smartHEAD itself. When a wrench extension is used, its angle correction coefficient must be calculate and added to the end fitting tool or program parameters.Transducer calibration date (CW)
Date of the last transducer torque calibration in clockwise direction.
Gyro calibration date (CW)
Date of the last transducer gyro calibration in clockwise direction.
Transducer calibration date (CCW)
Date of the last transducer torque calibration in counterclockwise direction.
Gyro calibration date (CCW)
Date of the last transducer gyro calibration in counterclockwise direction.
Next calibration date
Date of the next calibration expiration.