Pump

  1. On the Home view, go to Connected Devices tab.

  2. Select Pump , then press the Enter button to see the following:

    • Pump details

    • Pump Custom Identifier

    • Oil change - Remaining runtime

  3. To see more details press the Enter button.

Pump details

Select Pump details to see information about this connected unit, for example, article number, serial number, hardware version and the following:

  • Pump motor on time counts the cumber of seconds the motor has been running.

  • Pump intensifier on time counts the number of seconds the intensifier has been running.

  • Pump oil pressurization count counts the number of pressurizatons > 75% of max (=>1400 bars) that has passed since the last recorded oil change.

Pump Custom Identifier

Pump Custom Identifier is a field that can be used by the customer to identify the unit with help of an arbitrary ID. The custom ID is stored in the pump and is read by the hand controller at the system startup.

  1. To edit the custom ID, select the Pump Custom Identifier screen by pressing the Enter button.

  2. Press the More button to scan or to manually enter the new custom ID.

  3. Select Scan or Manual Input in the pop-up window for entering the new custom ID.

  4. For Manual input:

    Select Save & Exit in the pop-up window, or Reset and Exit to cancel this step.

    An event is emitted showing success (Custom ID is set appears).

The characters in the custom identifier must be ASCII characters with values < 128, please refer to an ASCII table.

The new custom ID will not be valid until the next start of the system.

Oil change - Remaining runtime

  1. When the oil and filter change has been completed, confirm the change by selecting Pump -> Oil change - Remaining runtime -> Oil and filter have been changed -> Yes.

    The next oil change date will be set one year in the future and the pump motor on time is cleared to 0.

    The new date is transferred to the pump and stored, the next oil and filter change date follows the pump and will be displayed in any hand controller that is connected to it.