Manual Mode Parameters
In the Default Manual Program, click on the Tensioning Manual icon in the tensioning area to edit the following parameters:
Name
Default manual hydraulic pressure (bar)
Max system hydraulic pressure (bar)
Parameter | Default | Description | Comment |
---|---|---|---|
Name | Manual Mode Step | String name of the step | Not used since the manual mode does not generate any results. |
Default manual hydraulic pressure (bar) | 1000 | Used to populate the manual mode set pressure window when the manual mode runs for the first time after a system start. | The default manual pressure makes sure that the operator does not just reuse a previous pressure from an earlier manual mode run. Set the default pressure to a value applicable to your application. Once the manual mode has been used, the system will assume that this is the pressure that suits the ongoing operation. The last used pressure will be used as the manual mode pressure until the system is powered off. It is always possible to change the target pressure in the controller GUI. |
Max system hydraulic pressure | 1980 | The highest pressure target that is allowed when using this configuration. | The system is using the lowest max pressure of its connected units. If any of the connected units have a lower max pressure, the pressurization will stop at this pressure level. |