Manual Mode Parameters

In the Default Manual Program, click on the Tensioning Manual icon in the tensioning area to edit the following parameters:

  • Name

  • Default manual hydraulic pressure (bar)

  • Max system hydraulic pressure (bar)

Parameter

Default

Description

Comment

Name

Manual Mode Step

String name of the step

Not used since the manual mode does not generate any results.

Default manual hydraulic pressure (bar)

1000

Used to populate the manual mode set pressure window when the manual mode runs for the first time after a system start.

The default manual pressure makes sure that the operator does not just reuse a previous pressure from an earlier manual mode run. Set the default pressure to a value applicable to your application. Once the manual mode has been used, the system will assume that this is the pressure that suits the ongoing operation. The last used pressure will be used as the manual mode pressure until the system is powered off. It is always possible to change the target pressure in the controller GUI.

Max system hydraulic pressure

1980

The highest pressure target that is allowed when using this configuration.

The system is using the lowest max pressure of its connected units. If any of the connected units have a lower max pressure, the pressurization will stop at this pressure level.