Viewing Synchronized Traces

Synchronizing traces older than software version 3.5 is not supported.

Synchronize and compare traces
  1. On the Home view, select the Reports Tab. On the left side, Results is automatically selected.

  2. In the Results window, select View all results.

  3. Select the traces to compare by marking the icon of the corresponding results. A selected trace icon turns blue.

    Up to 10 traces can be selected.

    Results without the icon do not support synchronization.

  4. Select the icon in the upper right hand corner, to open the sync trace view. When selecting the icon all selected result traces will be unchecked.

  5. In the Sync Trace Result View, select the preferred Sync method from the drop-down list.

    Select the trace types with the arrows in the upper right hand corner.

The Sync Trace Result View is shown below:

Point and click on image to see more information:

Sync methods

Sync methods are different strategies to synchronize traces by a specific value.

Traces can be synchronized by, for example, peak torque (highest torque reached for each trace). This shifts all traces along the x-axis, until each curve has its peak torque value at the exact same position on the x-axis.

All subsequent results are given an offset on the x-axis according to one of the following methods:

Sync method

Description

None

Default value. Selected traces are not synced.

Peak / Torque
Peak / Angle
Peak / Speed
Peak / Current
Peak / Gradient

All traces are synchronized towards the peak value, that is, shifted along the x-axis so that the peak values are at the same position on the x-axis as the peak value of the primary result.

Custom / Torque
Custom / Angle
Custom / Speed
Custom / Current
Custom / Gradient

  • All traces are synchronized towards a set value, shifted along the x-axis so that the set value are the same at the same position The set value of the primary result is used as reference point on the x-axis.

If sync method Custom is selected and none of the traces contains the configured value, an exclamation mark is shown in the custom value field.

If a result has no trace value that matches to the sync method it cannot be synchronized and its trace will not be shown. It will instead be shown with an exclamation mark.

If none of the traces are possible to synchronize, the error message “Unable to synchronize” is shown.