Method 2 (without ST Analyzer and Transducer)

  1. Position the pulse unit in a vice. Remove the oil plug positioned on either the front (A) or the back (B) of the pulse unit. Fill the pulse unit to 100% full. Assemble the oil plug.

  2. Assemble the tool and run in reverse for 3-5 seconds.

  3. Position the pulse unit in a vice. Remove the oil plug. Wait for all air bubbles to disappear (approximately 15 minutes) and the temperature to drop down to 20 degrees.

  4. Fill the pulse unit to 100% full.

  5. Reduce the oil in the pulse unit with a specified volume according to table using a 1 ml syringe. Assemble the oil plug.

    Oil volume to be

    reduced from 100%

    Approx. oil volume

    in pulse-unit

    ml

    ml

  6. Check torque and shut off function, for procedure see Testing/Measuring.

    • If everything is in order the amount of oil is right.

    • If everything is not in order repeat from step one.