Test conditions

Temperature pulse unit: approx. 20° C.

Air pressure: 6,3 bar (90psi) dynamic

Hose size: mm Hose length: 3 m

The tool should achieve the following values after maintenance:

Model

Free speed (r.p.m)

Pulse frequency (Hz)

Max Torque (minimum)(Nm)

Correct pulse frequency indicates that the air motor and the pulse unit are in good condition. If the pulse pulse frequency is to high - fill oil. If the pulse frequency is too low - reduce oil.