I/O Cables

For connecting multiple controllers with I/O cables distributing the emergency stop signal, use the maximum length according to the following table:

AWG 22 cable

Maximum total length

4 controllers

200 meters

5 controllers

140 meters

6 controllers

100 meters

8 controllers

70 meters

10 controllers

50 meters