Impulse Single-Step Start Stage Parameters
During the start stage, the tool rotates in a speed mode without any pulsing.
Parameter name | Description | Default Value |
---|---|---|
Soft start | Enables setting of the tool’s speed, angle and maximum torque to facilitate the bolt entering the thread. Selected by radio buttons. Off: Soft start is turned off. On:Soft start is turned on. | Off |
Speed | Defines the speed during the soft start. | 300 rpm |
Time | Defines the Soft start duration. | 400 ms |
Rehit detection | Early: Terminates the tightening immediately when an already tightened screw/bolt is detected. The tightening will be considered as NOK. Requires that Soft start is activated. Complete: Even though an already tightened screw/bolt is detected, the tightening is not terminated until all tightening steps have been executed. The tightening will be considered as NOK. To make a rehit detection when Soft start is not activated, the Rehit detection Complete option must be selected. Rehit detection Complete will not terminate the tightening until all tightening steps have been executed. The tightening will be considered a rehit if the speed fails to reach half the rundown speed, a rehit error is then indicated. Off: No rehit detection will be performed. Combination Soft start = Off and Rehit = Early is not allowed. | Off |
Use attachment tuning | Attachment tuning is selected by radio buttons. | No |
Gear ratio | Socket rotation speed = Tool speed / gear ratio. | 1.00 |
Efficiency tuning | For example 0.9 means 10% efficiency loss. | 1.00 |