Error Group | Error Category | Service Hints |
---|---|---|
none | item | none |
00 | Error updating tool SW | SW update issue. Try to connect tool to TTS2. It may give more info. |
01 | General SW error | General software issue. Update to latest software. |
02 | General SW error | General software issue. Update to latest software. |
03 | Front light error | Front light issue. Check cable and/or replace board. |
04 | Tool HMI error | Tool HMI error. 1. Update software using FFU flag. 2. Check cable. |
05 | General SW error | Motor control issue. 1. Check Main board (MB) - Motor control board (MCB) connection. 2. Update to latest software. |
06 | Tool memory error | Parameter memory issue. Try connecting tool to TTS2 to reset factory parameters. |
07 | Motortune error | Motor tune issue. 1. Update software to latest. 2. Try running tests in TTS2. 3. Check that the commutation board in the back of the tool is mounted correctly. A possible problem is that it isn't pushed properly into place. |
08 | General SW error | Parameter issue. Try connecting tool to TTS2 to reset factory parameters. |
09 | General SW error | Radio issue. 1. Check cable. 2. Check tool antennae cable. 3. Update software with FFU-flag. |
10 | Error updating radio SW | Radio SW update issue. 1. Check cable. 2. Check tool antennae cable. 3. Update software with FFU-flag. |
11 | General SW error | Radio issue. 1. Check cable. 2. Check tool antennae cable. 3. Update software with FFU-flag. |
12 | General SW error | Radio Bluetooth issue. 1. Check cable to radio module. 2. Update software with FFU-flag. |
13 | General SW error | Radio WIFI issue. 1. Check cable for radio module. 2. Update software with FFU-flag. |
14 | General SW error | Smart web-configuration issue. 1. Check cable for radio module. 2. Update software with FFU-flag. |
15 | RBU HW error | IAM issue. Try resetting SD-card checksums in TTS2. |
16 | RBU HW error | IAM issue. Try resetting SD-card checksums in TTS2. |
17 | General SW error | Parameter memory issue. Try connecting tool to TTS2 to reset factory parameters. |
18 | General HW error | Indicator board issue. |
19 | General SW error | General software issue. Update to latest software. |
20 | General SW error | Internal communication issue. Check Main board - Motor control board connection. |
21 | General SW error | Internal communication issue. Check Main board - Motor control board connection. |
22 | General SW error | General software issue. Update to latest software. |
23 | Backup battery error | Backup battery issue. Check backup battery connection. |
24 | General SW error | General software issue. Update to latest software. |
25 | Error updating motor control board | Motor control board (MCB) software update issue. 1. Check MCB connection. 2. Update to latest software. |
26 | General SW error | Motor control board communication error. 1. Check MCB connection. 2. Update to latest software. |
27 | General SW error | General hardware or software issue. |
28 | Power supply error | General power supply issue. |
29 | General SW error | Tool device identification issue. Connect to TTS2, may help to re-write tool identity. |
30 | General SW error | Tool device identification issue. Connect to TTS2, may help to re-write tool identity. |
31 | General SW error | Torque transducer issue. Check torque transducer and cable. |
32 | General tightening error | General tightening error. |
33 | Tool trigger error | Tool trigger issue. 1. Test trigger in TTS2. 2. Check that trigger is not broken. 3. Replace main board. |
34 | General SW error | Tightening trace issue. |
35 | General SW error | Tightening trace issue. |
36 | General HW error | Problem with hardware or connection between MB/MCB boards. 1. Check mechanical connection. 2. Replace MCB and/or MCB. |
37 | Function button error | Problem with changing tool direction. 1. Test function button in TTS2. 2. Update SW to latest version. |
38 | General HW error | Torque transducer issue. Check torque transducer and cable. |
39 | General HW error | General HW issue. |
40 | General HW error | General HW issue. Try replacing MB. |
41 | Error updating tool SW | SW update issue. Try to connect tool to TTS2, it may give more info. |
42 | Error updating tool SW | SW update issue. Try to connect tool to TTS2, it may give more info. |
43 | General HW error | Indicator board issue. <SRB HA does not use the indicator board> |
44 | General HW error | Second trigger issue. 1. Check cable and second trigger board. 2. Disconnect Gear ID board from front light board. 3. Replace front light board. |
45 | Error reading SRB HA tool config | Parameter memory issue. Try connecting tool to TTS2 to reset factory parameters. |
46 | General SW error | SRB HA - Smart result issue. 1. Try removing "RESULT.CSV" from IAM in folder HA. 2. Update software. |
47 | General SW error | SRB HA - Smart program issue. 1. Update to latest tool software. 2. Restore factory settings in TTS2. |
48 | General SW error | SRB HA - Smart program or Set&Go issue. 1. Update to latest tool software. 2. Restore factory settings in TTS2. |
49 | General SW error | General software issue. Update to latest software. |
50 | General HW error | IAM SD-card issue. |
51 | General SW error | General software issue. Update to latest software. |
52 | General SW error | Parameter memory issue. Try connecting tool to TTS2 to reset factory parameters. |
53 | Open end configuration error | Open end configuration issue. <SRB HA does not support this feature> |
54 | General SW error | General HW issue. |
55 | Front light HW error | Front light issue. 1. Check cable and/or replace board. 2. Update to latest software. |
56 | Push button error | Function button error. Runt function button test in TTS2. Replace button board or cable. |
57 | General SW error | HW input error. Try replacing Main board. |
58 | General SW error | HW input error. Try replacing Main board. |
59 | General SW error | Problems settings up Radio module in Access point mode. |
60 | Error updating indicator board SW | Indicator board issue. <SRB HA does not use the indicator board> |
61 | General SW error | Front light communication issue. Check cable and front light board. |
62 | RBU HW error | IAM SD-card issue. |
63 | General HW error | Main board FPGA error. 1. Try updating with latest software. 2. Replace main board. |
64 | General HW error | Main board FPGA update issue. 1. Try updating with latest software with FFU flag. 2. Replace main board. |
65 | General HW error | Parameter memory issue. Try connecting tool to TTS2 to reset factory parameters. |
66 | General SW error | Internal communication issue. Related to Radio or TTS2 communication. |
67 | General SW error | Internal communication issue. Related to Radio or TTS2 communication. |
68 | General SW error | Internal communication issue. Related to Radio or TTS2 communication. |
69 | General SW error | General SW issue. |
70 | General SW error | General SW/HW issue. |
71 | General SW error | General SW/HW issue. |
72 | General SW error | General SW issue. |
73 | Software update error | General SW update issue. |