Assembly Control Thin HID
Panel PC
Product Information
General Information
Safety Signal Words
The safety signal words Danger, Warning, Caution, and Notice have the following meanings:
DANGER | DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. |
WARNING | WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury. |
CAUTION | CAUTION, used with the safety alert symbol, indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. |
NOTICE | NOTICE is used to address practices not related to personal injury. |
Website
Information concerning our Products, Accessories, Spare Parts and Published Matters can be found on the Atlas Copco website.
Please visit: www.atlascopco.com.
ServAid
ServAid is a portal that is continuously updated and contains Technical Information, such as:
Regulatory and Safety Information
Technical Data
Installation, Operation and Service Instructions
Spare Parts Lists
Accessories
Dimensional Drawings
Please visit: https://servaid.atlascopco.com.
For further Technical Information, please contact your local Atlas Copco representative.
Safety Data Sheets MSDS/SDS
The Safety Data Sheets describe the chemical products sold by Atlas Copco.
Please consult the Atlas Copco website for more information www.atlascopco.com/sds.
Country of Origin
For the Country of Origin, please refer to the information on the product label.
Dimensional Drawings
Dimensional Drawings can be found either in the Dimensional Drawings Archive, or on ServAid.
Please visit: http://webbox.atlascopco.com/webbox/dimdrw or https://servaid.atlascopco.com.
Overview
Applications
The Industrial PC is a computer system which can support several applications, including:
An interface between the factory network and tightening equipment
A platform to operate error proofing systems with PC-based visualization
Technical Data
Assembly Control Thin HID | |
---|---|
CPU Type | 4x Arm®Cortex®-A53 @1,6 GHz, 1x Arm® Cortex®-M4 @400 MHz, 2D GPU und 3D GPU |
Mainboard | NXPi.mx8M |
Mass Storage | 32GB eMMC on board |
Ports | 4x DIO (24 V/up to 800 mA) Ethernet 1x 1 Gbit/s, 1x 10/100 Mbit/s USB 2x 2.0, 1x RS232, 1x RS485 |
Display | 21,5": LED TFT, 16:9, 1920 x 1080 pixel, brightness typ. 300 cd/m² |
Touch | glass, capacitive |
Wifi | n.a. |
User identification | RFID reader 13.56 MHz and 125 kHz |
Ingress Protection | IP54 (including Mounting Flange) |
Operating System | Linux |
Weight (Kg) | 7.45 |
Weight (lb) | 16.42 |
Dimensions [L × W × H] (mm) | 524×384×60 |
Ambient working temperature (°C) | 0°C to 40°C |
Ambient working temperature (°F) | 32°F to 104°F |
Internal I/O Module
Inputs/outputs | 4×digital I/O (24 VDC / up to 800 mA) |
Current per output (internally limited by PTC) | 0.2 A (up to 800 mA over all 4 outputs at a time loadable) |
Output | 24 VDC through 2 pole 3.5 mm Phoenix PCB connector (Phoenix article number: 1758856 MSTB 2.5 / 2-ST-5.08 BK - Leiterplattenstecker) |
Current consumption per input | 0.5 mA |

Outputs are protected against short circuits, overload, load dump (inductive voltage spikes) as well as the loss of ground connection.
Position of the S/N label

Installation
Installation Requirements
Primary Interfaces Connections
Ports and COM-connectors are present on the back side of the unit. The units ports can be used to connect the Panel PC to an external device.


1 | GPIO Connector | 5 | LAN 2 | 9 | Power Button |
2 | RS485/CAN Connector | 6 | USB 1 | 10 | Power Connector |
3 | RS232 | 7 | USB 2 | ||
4 | LAN 1 | 8 | +24V Out×2 |
Digital I/O Module
GPIO Connector
GPIO | PIN | Signal Name |
---|---|---|
1 | Dout1/Din1(Dout Imax=800mA) | |
2 | GND | |
3 | Dout2/Din2(Dout Imax=800mA) | |
4 | GND | |
5 | Dout3/Din3(Dout Imax=800mA) | |
6 | GND | |
7 | Dout4/Din4(Dout Imax=800mA) | |
8 | GND |
Serial Port Connector (COM)
Phoenix Contact Connector 180° DFMC 0,54-ST-2,54 (Phoenix 1844594)
Serial Port | PIN | RS232 |
---|---|---|
1 | VIN | |
2 | GND | |
3 | T×D | |
4 | R×D | |
5 | RTS | |
6 | CTS | |
7 | +5 VDC | |
8 | GND |
RS485
Phoenix Contact Connector 180° DFMC 0,54-ST-2,54 (Phoenix 1844594)
Serial Port | PIN | RS485 |
---|---|---|
1 | VIN | |
2 | GND | |
3 | RS485 A | |
4 | CAN H | |
5 | RS485 B | |
6 | CAN L | |
7 | +5 VDC | |
8 | GND |
CAN Address Switch
Serial Port | Switch | Signal Name |
---|---|---|
1 | Address 1 | |
2 | Address 2 | |
3 | Address 3 | |
4 | Address 4 | |
5 | CAN Termination | |
6 | RS485 Termination |
Secondary Interfaces Connections
Loosen the cap (1) on the bottom of the unit. Once removed, an additional USB 2.0 Type A adaptor is available example for service purposes.

Software Installation Requirements
Software update / installation is done through Update Server. Information is available on Servaid.
Power Supply Cable
Power Supply Cable 100-240 VAC
The power supply cable must be a three wire AWG 16 with length in-between 1.5 meters and 4.5 meters.
The plug of the power supply cable must be easily accessible. For instance, in a main wall outlet or in a cabinet outlet. The outlet must be marked as safety disconnect in case of emergency.
Use one of the cable types listed below;
4222 1801 13 | Power cable EU - type E/F |
4222 1802 13 | Power cable US - type B |
4222 1803 13 | Power cable UK - type G |
4222 1804 13 | Power cable IN/ZA - type M |
4222 1805 13 | Power cable CH - type J |
4222 1806 13 | Power cable IT - type L |
4222 1807 13 | Power cable AU - type I |
4222 1809 13 | Power cable CN - type I |
4222 1810 13 | Power cable BR - type N |
4222 1811 13 | Power cable IL - type H |
External Circuit Breaker
The Panel PC must be installed with an external two pole circuit breaker rated current 6 A. Example Eaton FAZ-C6/2.
Installation Instructions
Assembling the Panel PC

Only qualified personnel shall assemble and operate the Panel PC.
Only suspended or standing assembly with standard screen of the Panel PC is permitted. Vertical screen orientation is not permitted.
Assemble the Panel PC as follows:
Loosen the two screws on the connection console cover.
Partly install the two bottom screws first. The original size of these screws is M6×18 mm.
The distance between the Panel PC and the screw head should be around 13 mm.
Hook the Panel PC on to the corresponding holes in the console.
Install the two upper screws and tighten them including the two bottom screws.
Connect all cables to the Panel PC and put the connection cover back in position.
Suspended Assembly

Raised Assembly

Connecting the Power Supply Cable

Connect the power supply plug (1) to the power connector (2).
Connect the power supply cable plug (3) into the mains socket.
Switch on the power button.
Operation
Ergonomic Guidelines
Consider your workstation as you read through this list of general ergonomic guidelines and see if you can identify areas for improvement in posture, component placement, or work environment.
Take frequent breaks and change work positions frequently.
Adapt the work area to your needs and the work task.
Adjust for convenient reach range by determining where parts or tools should be located to avoid static load.
Use workstation equipment such as tables and chairs appropriate for the work task.
Avoid work positions above shoulder level or with static holding during assembly operations.
When working above shoulder level, reduce the load on the static muscles by reducing the weight of the load. You can also reduce the load on the static muscles by holding the load close to the body.
Make sure to take frequent breaks.
Avoid extreme arm or wrist postures, particularly for operations requiring a degree of force.
Adjust for convenient field of vision by minimizing movement of the eyes and head during the work task.
Use the appropriate lighting for the work task.
Use ear protection equipment in noisy environments.
Use dust extraction system or mouth protection mask in dusty environments.
Operating Instructions
Opening / Closing the Panel PC

Remove the 4 screws on the backside of the Panel PC.
Carefully lift the back unit of the Panel PC to a maximum 25° to access the internal cabling at the front.
Be careful not to damage USB.
Carefully disconnect all cables from the front unit of the panel PC before removing any other parts.
The connectors, and especially the display connectors, must be handled with care to prevent damage.
Put the front unit aside with care not to damage the glass surface.
Assemble in reverse order.
Make sure that the yellow gasket is in correct position before you put the front back in position.
Put all screws back in position and tighten them lightly.
Then tighten them all to a torque of 1.4 Nm.
By opening the housing of Assembly Control Thin (Panel PC), all warranty claims are lost.
Additional Information

The rear surface of the panel PC can become very warm. Be careful when touching the rear surface.
Turning the Panel PC On and Off
Open the cover of the connection console.
Press the power button (1) to turn on the Panel PC. The Panel PC boots automatically into the browser’s kiosk mode
To switch to console mode, press the key combination Ctrl+ALT+F1.
Enter User: Root and Password: ThinClient.
Enter Shutdown to close the ThinClient.
Once the system has closed it is possible to press the power button to start again.
The system can also be set to start or sleep by settings into a server-/device-based middleware. The Server-/device-based middleware is not a part of the delivery.
Service
Preventing ESD Problems
The components inside the product and controller are sensitive to electrostatic discharge. To avoid future malfunction, make sure that service and maintenance is carried out in an ESD approved work environment. The figure below shows an example of an appropriate service work station.

Replacing the BIOS battery
When the BIOS buffer battery is replaced, it should be of original part type CR1220.
Dispose used batteries according to the local or regional regulations or instructions.
Maintenance recommendations
The Panel PC can generally be operated without maintenance, but should be cleaned regularly in very dusty environments.
For preventive maintenance purposes and depending on operating conditions and availability requirements, the power supply may be replaced as a precautionary measure.
If the device does not function flawlessly, it should be shut down immediately and inspected. During an overhaul, all parts should be carefully cleaned and damaged and worn out parts replaced.
Recycling
Environmental Regulations
When a product has served its purpose it has to be recycled properly. Dismantle the product and recycle the components in accordance with local legislation.
Batteries shall be taken care of by your national battery recovery organization.
Recycling Instructions

Pos. | Part | Recycle as |
---|---|---|
1. | Front module | Aluminum, Glass |
2. | Power LED Module | Electronics |
3. | RFID Reader | Electronics |
4. | Connector plate | Aluminum |
5. | Cable Clamp | Plastic |
6. | Screw | Metal |
7. | Power Supply | Electronics |
8. | Space bolt | Metal |
9. | Cover Sheet | Aluminum |
10. | Screw | Metal |
11. | Screw | Metal |
12. | Mainboard | Electronics |
13. | Interface Plate | Aluminum |
14. | On / Switch | Electronics |
15. | Plug | Plastic |
16. | Screw | Metal |
17. | Gasket | Rubber |
18. | Housing | Aluminum |
19. | External USB | Electronics |
20. | Screw | Metal |