Replacing the wire

It is possible to replace the wire without releasing the spring and without dismantling the balancer.

  1. Fully retract the wire and make sure that the wire end is visible in the balancer housing slot.

  2. Lock the wire drum.

    Refer the below link to lock the wire drum correctly:

    Locking the wire drum

    WARNING

    Risk of snap back

    An accidental release of the wire drum can cause a snap back of the wire can cause damage and serious injury.

    • Make sure the wire drum is correctly locked

  3. Remove the workload.

  4. Pull out the wire end through the balancer housing slot by pushing the opposite wire end.

  5. Remove the locking bush.

  6. Pull out the wire through the balancer housing opening.

  7. Push the replacement cable through the balancer housing opening and further out through the balancer housing slot.

  8. Attach the locking bush.

  9. Push the wire back into the housing.

  10. Attach the workload.

    WARNING

    Risk of Injury

    A change of the workload weight can cause unexpected movements and injury.

    • Do not change the workload weight when replacing the wire.

  11. Unlock the wire drum.