Screw pickup

Screw pickup helps the operator to pick up a screw before starting the tightening. The first start signal will trigger the screw pickup function and the second start signal will trigger the tightening. Meaning that the start signal must be pressed/triggered twice to activate the tightening procedure.

Tightening procedure when Screw pickup is enabled:

  1. Activate start signal to pick up screw.

  2. Place the screw in the correct position.

  3. Activate the start signal again to trigger the tightening.

Parameter

Description

Not aligned limit

Vacuum level required to acknowledge that a screw has been picked up.

Aligned limit

Vacuum level required to acknowledge that the screw is aligned.

Screw pickup

Indicates if the function is enabled.

Screw pickup can be used both for handheld and automatic operations. The parameters Not aligned limit and Aligned limit requires the use of Vacuum Pump MT, which is only compatible with a controller with MTF6000 revision C or later.

If screw pickup is enabled, the following parameters can be configured:

Parameter

Description

Vacuum pump

Starts vacuum pump upon activating screw pickup function

Rotate bit on pickup

Bit rotates slowly CCW to help attach the bit to the screw.

Timeout

Timeout is used to set an interval how long the pickup should take. If the time is exceeded the controller will leave the busy state and go back to idle.

Guiding light

Activates the MT tool guiding light upon activating screw pickup function.

Pickup guide

Vacuum pickup guide is available with Vacuum pump MT (8432 0854 00) and a controller with MTF6000 revision C or later. Click PICKUP GUIDE to open the wizard. The vacuum starts automatically if the vacuum pump MT is connected.

On the wizard page, you can set the limits by moving the limit indicators up and down. A two-step setup guide is also available by clicking SETUP GUIDE:

  1. Follow the instructions on the screen to set the value when the screw is picked up but not aligned.

  2. Follow the instructions on the screen to set the value when the screw is picked up and aligned.

You can always manually update the values afterwards.