Custom View

The custom view makes it possible to customize the last view on the controller. The selected information will only be displayed during the selected Pset. If no Pset is selected the screen will be blank.
The screen can be configured to show one to four fields. For each field it is possible to display general or step information.

The first field have a white background, the following have grey background. This is to give a focal point and have no other intended meaning.

General data

Parameter

Description

Final torque

Shows the final torque of the tightening. Final torque can be configured in the general settings of the Pset.

Peak torque

Shows the maximum achieved torque in the tightening.

Tracking torque

Follows the torque during the tightening.

Final angle

Shows the final angle of the tightening. Final angle can be configured in the general settings of the Pset.

Total angle

Shows the total angle of the tightening.

Tracking angle

Follows the angle during the tightening.

Tightening error

Shows the current error message, blank if no current error.

Pset name and number

Shows Pset number and name.

Controller date

Controller date.

Controller name

Controller name (configured under Controller settings).

Station name

Station name (configured under Controller settings).

Line name

Line name (configured under Controller settings).

Logged in user

Displays if any user level is logged in (L1-L3) or "-" if no user is logged in.

Tightening duration

The time in seconds of the last tightening.

Tool serial number

The serial number of the connected tool.

Tool type

The type of the connected tool.

Calibration date

Date of last calibration.

Tool statistics

Tool statistics, displays the OK and NOK tightenings since last calibration.

Select source

Displays the source of Pset and batch sequence selections.

Controller time

Controller time.

Tool temp

Current temperature of tool.

Vacuum pressure

Displays real time vacuum pressure in kPa.
Only works with Vacuum pump MT (8432 0854 00) and a controller with MTF6000 revision C or later).

Step data

Parameter

Description

Step number

Selects from which step the parameter "Step data" shall get its values from.

Step peak torque

Shows the maximum achieved torque in the selected step.

Step clamp torque

Shows the achieved clamp torque in the selected step.

Step transition torque

Shows the maximum last measured torque in the selected step.

Step angle

Shows the achieved angle for the selected step.

Step clamp angle

Shows the achieved clamp angle in the selected step.

Seating point

Shows the seating torque of the step.

Tightening angle

Shows the tightening angle for the selected step