Custom View
The custom view makes it possible to customize the last view on the controller. The selected information will only be displayed during the selected Pset. If no Pset is selected the screen will be blank.
The screen can be configured to show one to four fields. For each field it is possible to display general or step information.
The first field have a white background, the following have grey background. This is to give a focal point and have no other intended meaning.
General data
Parameter | Description |
|---|---|
Final torque | Shows the final torque of the tightening. Final torque can be configured in the general settings of the Pset. |
Peak torque | Shows the maximum achieved torque in the tightening. |
Tracking torque | Follows the torque during the tightening. |
Final angle | Shows the final angle of the tightening. Final angle can be configured in the general settings of the Pset. |
Total angle | Shows the total angle of the tightening. |
Tracking angle | Follows the angle during the tightening. |
Tightening error | Shows the current error message, blank if no current error. |
Pset name and number | Shows Pset number and name. |
Controller date | Controller date. |
Controller name | Controller name (configured under Controller settings). |
Station name | Station name (configured under Controller settings). |
Line name | Line name (configured under Controller settings). |
Logged in user | Displays if any user level is logged in (L1-L3) or "-" if no user is logged in. |
Tightening duration | The time in seconds of the last tightening. |
Tool serial number | The serial number of the connected tool. |
Tool type | The type of the connected tool. |
Calibration date | Date of last calibration. |
Tool statistics | Tool statistics, displays the OK and NOK tightenings since last calibration. |
Select source | Displays the source of Pset and batch sequence selections. |
Controller time | Controller time. |
Tool temp | Current temperature of tool. |
Vacuum pressure | Displays real time vacuum pressure in kPa. |
Step data
Parameter | Description |
|---|---|
Step number | Selects from which step the parameter "Step data" shall get its values from. |
Step peak torque | Shows the maximum achieved torque in the selected step. |
Step clamp torque | Shows the achieved clamp torque in the selected step. |
Step transition torque | Shows the maximum last measured torque in the selected step. |
Step angle | Shows the achieved angle for the selected step. |
Step clamp angle | Shows the achieved clamp angle in the selected step. |
Seating point | Shows the seating torque of the step. |
Tightening angle | Shows the tightening angle for the selected step |