Batch parameters
A batch is a series of tightenings with one defined Pset.
Parameter | Description |
Pset number | Number of the Pset to use. |
Batch size | The number of tightenings with the selected Pset. |
Repair mode | Enabled/Disabled. If enabled the loosening trigger will automatically be disabled until a tightening error. When the loosening trigger is enabled the tool trigger is disabled. After a loosening, the repair Pset mode is enabled. |
Increment batch counter on | OK or OK/NOK. Should the batch counter increase on OK tightenings only or on OK and Not OK tightenings. |
Fail on NOK no. | The maximum number of allowed failed tightenings during a batch. |
Repair Pset | Select a repair Pset. |
Repair limit | If a tightening fails, the repair limit is incremented. If the repair attempts exceed the repair counter the whole batch sequence is failed. |
From start | The maximum execution time for the batch step. If the batch step takes longer time than this, the batch sequence is failed and aborted with an error message. |