Batch parameters

A batch is a series of tightenings with one defined Pset.

Parameter

Description

Pset number

Number of the Pset to use.

Batch size

The number of tightenings with the selected Pset.

Repair mode

Enabled/Disabled.

If enabled the loosening trigger will automatically be disabled until a tightening error. When the loosening trigger is enabled the tool trigger is disabled. After a loosening, the repair Pset mode is enabled.

Increment batch counter on

OK or OK/NOK. Should the batch counter increase on OK tightenings only or on OK and Not OK tightenings.

Fail on NOK no.

The maximum number of allowed failed tightenings during a batch.

Repair Pset

Select a repair Pset.

Repair limit

If a tightening fails, the repair limit is incremented. If the repair attempts exceed the repair counter the whole batch sequence is failed.

From start

The maximum execution time for the batch step. If the batch step takes longer time than this, the batch sequence is failed and aborted with an error message.

From tightening

The maximum execution time for a batch step counting from the start of the first tightening. If the batch step takes longer time than this, the batch sequence is failed and aborted with an error message.