General settings

Parameter

Description

Pset name

Is shown in Pset list. The Pset name is stored with the result and will be displayed in the controller result view.

Pset revision

Revision number of the Pset.

Pset created

The date when the Pset was created.

Pset modified

The date when the Pset was last modified.

Configured tool name

The tool type the Pset was linked to (model type in text).

Min. total time

Minimum time a tightening must run to pass as a tightening.

Max. total time

Maximum time a tightening can run to pass as a tightening.

Min. total angle

Minimum number of degrees the tool must turn during a tightening.

Max. total angle

Maximum number of degrees the tool is allowed to turn during a tightening.

Trigger lost torque

An error will be sent if the tool button is released after the Trigger lost torque value have been passed but before the tightening is completed.
This is to make sure that no error codes will be sent if the tool button is pressed by mistake

Graph start step

The number of the step from which the graph is started.

Torque tuning

Adjust torque calibration for this Pset. The controller multiplies measured torque with the factor “(1.0 – Torque tuning)”. So a positive Torque tuning increases the applied torque. Torque tuning can be +/-0.1

Angle range start step

Defines from which step the result angle will start measuring.

Angle range stop step

Defines from which step the result angle will stop measuring at.

Min. angle range

Minimum number of degrees the tool must turn between angle range start and stop step.

Max. angle range

Maximum number of degrees the tool is allowed to turn between angle range start and stop step.

Requested Bit

Disables tool if requested bit is not picked from Accessory Bus bit selector. If no Accessory Bus bit selector is connected the tool will still be disabled. If set to None, parameter is not active.

Final report step

Defines which tightening step in a Pset should report the final torque in the result. It is usually the last step in a Pset but can sometimes be another step.

Final report torque

Decides if the final report step should report the peak, clamp or final torque.
In most cases peak and final torque will be the same, but not in the angle step where peak torque can be higher than final torque.

Final report angle

Decides if the final report step should report the step, clamp or tightening angle.

Final seating point angle start step

Determines from what step the Final seating point angle result parameter should be calculated from.

Bit slip detection

(Licenced feature)

Bit slip is a function to detect when the bit slips out of the joint. It is a sign that the bit or the screw head is damaged.
Bit slip is not enabled at torques lower than 10% of tool max torque.
When bit slip detection is enabled, the screw driver will stop when a torque drop is detected and an error message will be displayed in the controller

If bit slip occurs during a Seating Control Step or a Torque Seating Monitoring and bit slip is disabled, a seating can falsely be detected.

Damaged thread detection

(Licenced feature)

Will detect if the screw's threads have been damaged.

Tool rehit

Pset defined rehit parameter that can override the global controller settings for rehit.

  • Controller settings - Rehit is controlled from the original rehit controller parameter.

  • Disabled - Rehit is disabled (regardless of controller setting rehit value).

  • Enabled - Rehit is enabled (regardless of controller setting rehit value).