Product data
Operating torque measuring range: 5 [N·m] - 25 [N·m] / 3.7 [lb·ft] - 18.4 [lb·ft]
Drive: mm.
Overall length: 177 mm.
Operating torque range: from 20% to 100% of the capacity
Torque measurement accuracy (within the operating torque range): 2%
For the ISO 6789 part 2, consider the following accuracy:
Measurement accuracy < 10 Nm: ± 6%
Measurement accuracy > 10 Nm: ± 4%
Mechanical repeatability click: ± 4%
Overload capacity: 120 % of nominal capacity
Maximum angular speed: 250 °/s
Angle measurement accuracy: ± 3.6 ° / 360 ° (at 6 ° per second)
Temperature stability of torque measurement: +10 °C to +40 °C (10 °F to 104 °F)
Tightening results memory capacity: 8100 Data sets (maximum)
MWR-25 TA Reference Firmware version: 3.0.0
Power supply: 1.2 V rechargeable battery