Event Codes
Different types of events are used to notify the user of certain state changes or occurrences in the system. Each event requires a different action.
Some of the procedures described can only be performed by Atlas Copco Service personnel.
For more information about a specific event code, use the below filters or enter the event code search criteria in the search box.
Event Code | Event Type | Event Name | Beschrijving | Procedure | Log / Display / Ack / Conf | Available for | Groepen |
|---|---|---|---|---|---|---|---|
none | item | none | none | none | column | list | list |
1000 | Info | Controller gestart | The controller is started. | Log Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 Power Focus 500 ToolsControl | Controller and Tool | |
1001 | Waarschuwing | Serienummer controller bijgewerkt | Generated at start-up if IT-board box serial number (controller serial number) differs from AUX-board box serial number. AUX-board is considered to be non-replaceable in field. The controller will reboot when the serial number is updated. | Replace IT-board or box. | Log Display Ack Conf | Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 | Controller and Tool |
1010 | Info | Gereedschap aangesloten | A tool is connected. | Log Display Conf | Flex Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 Power Focus 500 ToolsControl | Controller and Tool | |
1011 | Info | Gereedschap losgekoppeld | A tool is disconnected. | Log Display Conf | Flex Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 Power Focus 500 ToolsControl | Controller and Tool | |
1012 | Info | Tool Rejected Controller Connection | This event can occur if the tool is into a skip-zone. | Verify if another controller is connected to the tool. Controleer of de lichtaansluiting correct is ingesteld. | Log Display Conf | Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Controller and Tool |
2000 | Waarschuwing | Battery Low | Replace battery. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl XB | Gereedschap | |
2001 | Waarschuwing | Battery Empty | Replace battery. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl XB | Gereedschap | |
2002 | Waarschuwing | Gereedschap gezondheid batterij laag | Tool battery health problem is detected. | Replace battery. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Gereedschap |
2004 | Waarschuwing | Gereedschap is niet van gewenst type | Tool has been replaced by a tool with a different Tool Max Torque. | Change tool. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Gereedschap |
2006 | Waarschuwing | Gereedschap gezondheid reservebatterij laag | The backup battery in the tool has too poor performance. | The backup battery should be replaced. | Log Display Ack Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Gereedschap |
2007 | Waarschuwing | Gereedschap reservebatterij ontbreekt of defect | Gereedschap reservebatterij ontbreekt of defect | Het plaatsen van een batterij | Log Display Conf | Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Gereedschap |
2008 | Waarschuwing | Gereedschap fout reservebatterij | Gereedschap fout reservebatterij | Replace battery. | Log Display Conf | Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Gereedschap |
2009 | Waarschuwing | Gereedschap spanning reservebatterij laag | The controller's backup battery is almost empty. | Replace battery. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Gereedschap |
2010 | Fout | Onjuiste versie van gereedschapssoftware | Tool and controller software versions not compatible. | Service tool - update tool software. | Log Display Ack Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Gereedschap |
2012 | Waarschuwing | Storing in communicatie gereedschap | Communication between tool and controller interrupted. | Relocate antenna placement. | Conf | Flex Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 Power Focus 500 ToolsControl | Gereedschap |
2013 | Waarschuwing | Illegale ringpositie | Tool direction switch in faulty position. | If occurring frequently - service the tool. | Log Display Conf | Flex Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Gereedschap |
2014 | Waarschuwing | Gereedschap oververhit | Gereedschap oververhit | Allow tool to cool down. | Log Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl XB | Gereedschap |
2015 | Fout | Fout in gereedschapstemperatuursensor | SRB, TBP and IxB tools only. | Service the tool. | Log Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Gereedschap |
2016 | Waarschuwing | Gereedschap pulseenheid oververhit | Gereedschap pulseenheid oververhit Tool is not locked, but the warning is displayed whenever the tool is started as long as the pulse unit temperature is over threshold. | Allow tool to cool down. | Log Display Conf | Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Gereedschap |
2019 | Waarschuwing | Gereedschap kon motor niet starten | Gereedschap batterijstoring | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Gereedschap | |
2020 | Waarschuwing | Gereedschap vereist motorafstelling | Gereedschap vereist motorafstelling | Perform a motor tuning. | Log Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl XB | Gereedschap |
2021 | Waarschuwing | Motorafstelling mislukt | Motorafstelling mislukt | Complete motor tuning or service the tool. | Log | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Gereedschap |
2022 | Info | Motorafstelling voltooid | Motorafstelling voltooid | Log Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Gereedschap | |
2023 | Waarschuwing | Het gereedschap vereist afstelling met open einde | Het gereedschap vereist afstelling met open einde | Perform open end tuning. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Gereedschap |
2024 | Waarschuwing | Afstellen met open einde mislukt | Afstellen met open einde mislukt | Try to perform open end tuning one more time. If it fails again, service the tool. | Log Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Gereedschap |
2025 | Info | Afstellen met open einde geslaagd | Afstellen met open einde geslaagd | Log Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Gereedschap | |
2026 | Waarschuwing | Positioneren met open einde mislukt | Positioneren met open einde mislukt | Press the tool trigger again and wait for the positioning to be completed. If it fails again, service the tool. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Gereedschap |
2027 | Waarschuwing | Gebruik beperkt vanwege hoge gereedschapstemperatuur. | Temperature limit value has been reached. Tightening has been inhibited to reduce risk for tool shutting down due to overheating. | Wait until tool temperature has been reduced. | Log Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl XB | Gereedschap |
2030 | Fout | Tool Memory Failure: Change Tool | Gereedschap accessoiregeheugen corrupt | Service the tool. | Log Display Ack Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Gereedschap |
2031 | Fout | Gereedschap accessoiregeheugen corrupt | Gereedschap accessoiregeheugen corrupt | Service the tool accessory. | Log Display Ack Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Gereedschap |
2040 | Fout | Systeemcontrole mislukt | Log Display Ack Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl XB | Gereedschap | ||
2041 | Fout | Fout koppelomvormer | Will be generated either on calibration error or if tool reports transducer error. | Service the tool. | Log Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl XB | Gereedschap |
2042 | Fout | Fout hoekomvormer | Service the tool. | Log Display Ack Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Gereedschap | |
2043 | Fout | Tool Ground Fault Error | Service the tool. | Log Display Ack Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Gereedschap | |
2044 | Info | Onderhoudsinterval gereedschap verstreken | Indicates that servicing of the tool is needed. Triggered when the number of set tightenings has been exceeded. | Perform service of tool. | Log Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Gereedschap |
2045 | Waarschuwing | Kalibratiegegevens gereedschap ongeldig | If validation of calibration data fails. | Service the tool. | Log Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl XB | Gereedschap |
2046 | Info | Gereedschap Gereedschap, volgende kalibratiedatum is verstreken | Indicates that calibration of tool is needed. Triggered when calibration alarm is enabled in settings and the current time is greater than next calibration date. | Service the tool. | Log Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Gereedschap |
2048 | Info | Gereedschap kalibratiewaarde bijgewerkt door QA-apparaat | Tool calibration was updated when a calibration with a QA device was performed. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Gereedschap | |
2050 | Fout | Gereedschapsparameterbestand wordt niet ondersteund | De vereiste startparameters ontbreken. | Onjuiste gereedschapsparameters. | Log Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Gereedschap |
2060 | Info | Onverwacht trekkergedrag | Used to prevent start of tool if accessory is connected. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Gereedschap | |
2071 | Fout | Tool Memory Corrupt | Tool descriptor is corrupt. | Service the tool. | Log Display Conf | Flex Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Gereedschap |
2072 | Info | Unknown Device Connected | Log Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Gereedschap | ||
2073 | Waarschuwing | Gereedschap storing in trekkerbewaking | HW channel failure. Mismatch between hardware and software of tool trigger. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Gereedschap | |
2074 | Waarschuwing | Gereedschap storing in indicatorbord | Gereedschap storing in indicatorbord | Service the tool. | Log Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Gereedschap |
2075 | Waarschuwing | Gereedschap storing in ventilatorspanning | Gereedschap storing in ventilatorspanning | Service the tool. | Log Display Conf | Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Gereedschap |
2076 | Waarschuwing | Gereedschap storing in busspanning accessoire | Gereedschap storing in busspanning accessoire | Service the tool. | Log Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Gereedschap |
2077 | Waarschuwing | Gereedschap fout in trekkersensor | Gereedschap fout in trekkersensor | Service the tool. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Gereedschap |
2078 | Info | Tool Tightening Program Updated | Gereedschap geblokkeerd vanwege update aandraaiprogramma | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Gereedschap | |
2079 | Fout | Gereedschapskabel wordt niet ondersteund | Tool cable is corrupt. The chip in the cable is not responding or is damaged. | Switch cable. | Log Display Conf | Flex Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Gereedschap |
2080 | Fout | Gereedschap batterijstoring | DC voltage too high or too low. Batterijstoring | Contact the Atlas Copco service representative and send back battery to Atlas Copco (do not reuse it!). | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl XB | Gereedschap |
2081 | Fout | Gereedschap stroomlimiet bereikt | The current limit value has been reached and the drive is disabled. | Service the tool. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Gereedschap |
2082 | Fout | Gereedschap fout in stroommeting | Fout in stroommeting Current cannot be measured with a reliable result. | Service the tool. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl XB | Gereedschap |
2083 | Fout | Gereedschap interne fout | Various internal hardware errors. | Service the tool. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl XB | Gereedschap |
2084 | Fout | Gereedschap interne softwarefout | Gereedschap interne softwarefout | Service the tool. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl XB | Gereedschap |
2085 | Fout | RBU-fout gereedschap | An RBU error was detected by the tool software. | Controleer of de gereedschapskabel goed is aangesloten If error is still present then service the tool. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Gereedschap |
2086 | Fout | Gereedschap afgeslagen | Tool motor is stalling. | Service the tool. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl XB | Gereedschap |
2087 | Waarschuwing | Gereedschap motorstroom hoog | Tool motor current limit value is exceeded, and the tool is locked. Tool will enter failsafe mode. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl XB | Gereedschap | |
2088 | Waarschuwing | Gereedschap batterijstroom hoog | Gereedschap batterijstroom hoog | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl XB | Gereedschap | |
2089 | Waarschuwing | Gereedschap spanning aandrijving laag | Tool drive voltage is below the monitored lower voltage limit value. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Gereedschap | |
2090 | Waarschuwing | Gereedschap spanning aandrijving hoog | Tool drive voltage is above monitored higher voltage limit value. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Gereedschap | |
2091 | Waarschuwing | Gereedschap hoofdprintplaat fout | Gereedschap hoofdprintplaat fout | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl XB | Gereedschap | |
2092 | Waarschuwing | Gereedschap voedingsmodule fout | Gereedschap voedingsmodule fout | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Gereedschap | |
2093 | Waarschuwing | Gereedschap oliepeil pulseenheid laag | The oil level of the connected pulse tool is low. | Service the tool. | Log Display Conf | Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Gereedschap |
2094 | Waarschuwing | Gereedschap oliepeil pulseenheid leeg | The oil level of the connected pulse tool is below required operational level. | Service the tool. | Log Display Ack Conf | Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Gereedschap |
2095 | Waarschuwing | Gereedschap communicatie met batterij verloren | Tool lost communication with battery. | Make sure battery is snugged correctly. Otherwise change battery. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Gereedschap |
2096 | Fout | Gereedschap softwareversie komt niet overeen. | Tool battery software incompatible with tool software. | Update software. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Gereedschap |
2097 | Waarschuwing | Tool export timeout | The tool export timed out. Please export the logs via USB cable attached to the tool. | Log export. | Log Display Ack Conf | IxB | Gereedschap |
2100 | Info | STwrench + smartHEAD 15 | STwrench smartHead is verwijderd | Reconnect smartHEAD and restart the wrench. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Gereedschap |
2101 | Waarschuwing | Sleutel aandraaien terwijl vergrendeld | A wrench tightening was performed when the tool status was locked in the controller. | Wait until the tool status in controller is unlocked. | Log Display Conf | Power Focus 6000 Power Focus 8 ToolsControl | Gereedschap |
2120 | Waarschuwing | Unable To Start: Tool Has No Active Torque Transducer | Log Display | Flex | Gereedschap | ||
2121 | Waarschuwing | Omvormers zijn uitgeschakeld voor verbonden gereedschap | Log Display | Flex | Gereedschap | ||
2122 | Waarschuwing | Unable To Start: Tool Is Missing Required Torque Transducer | Change to a tool with multiple torque transducers or update the setting "Require dual torque" in Tool Configuration. | Log Display | Flex IxB | Gereedschap | |
2123 | Waarschuwing | Unable To Start: Tool Is Missing Required Angle Transducer | Change to a tool with multiple torque transducers or update the setting "Require dual torque" in Tool Configuration. | Log Display | Flex | Gereedschap | |
2125 | Fout | Torque Transducer Error On Transducer 2 | There is an error on torque transducer 2 of a tool with multiple transducers. | Service the tool. | Log Display | Flex | Gereedschap |
2127 | Fout | Gereedschap kalibratiefout koppelomvormer | There is an error on the torque transducer. | Service the tool. | Log Display | Flex Synchronized tightening | Gereedschap |
2129 | Fout | Tool Torque Transducer: Shunt Test Failed | There is an error on the torque transducer. | Service the tool. | Log Display | Flex Synchronized tightening XB | Gereedschap |
2131 | Fout | Tool Torque Transducer: Zero Offset Compensation Failed | There is an error on the torque transducer. | Ensure the tightening is started with zero torque on the tool. Service the tool. | Log Display | Flex Synchronized tightening | Gereedschap |
2133 | Fout | Gereedschap koppelomvormer hardwarefout | There is an error on the torque transducer. | Service the tool. | Log Display | Flex Synchronized tightening | Gereedschap |
2135 | Fout | Gereedschap kalibratiefout koppelomvormer Overflow In A/D Converter | There is an error on the torque transducer. | Service the tool. | Log Display | Flex Synchronized tightening | Gereedschap |
2136 | Fout | Gereedschap koppelomvormer kalibratiefout op secundaire omvormer | There is an error on torque transducer 2 of a tool with multiple transducers. | Service the tool. | Log Display | Flex | Gereedschap |
2137 | Fout | Gereedschap kalibratiefout koppelomvormer Shunt Test Failed On Transducer 2 | There is an error on torque transducer 2 of a tool with multiple transducers. | Service the tool. | Log Display | Flex | Gereedschap |
2138 | Fout | Gereedschap kalibratiefout koppelomvormer Zero Offset Compensation Failed On Transducer 2 | There is an error on torque transducer 2 of a tool with multiple transducers. | Ensure the tightening is started with zero torque on the tool. Service the tool. | Log Display | Flex | Gereedschap |
2139 | Fout | Gereedschap koppelomvormer hardwarefout op secundaire omvormer | There is an error on torque transducer 2 of a tool with multiple transducers. | Service the tool. | Log Display | Flex | Gereedschap |
2140 | Fout | Gereedschap kalibratiefout koppelomvormer Overflow In A/D Converter On Transducer 2 | There is an error on torque transducer 2 of a tool with multiple transducers. | Service the tool. | Log Display | Flex | Gereedschap |
2141 | Fout | Tool Angle Transducer Error On Transducer 2 | Will be generated if tool reports transducer error from angle transducer 2. | Service the tool. | Log Display Conf | Flex Power Focus 6000 ToolsControl Power Focus 8 Synchronized tightening Power Focus 500 | Gereedschap |
2142 | Fout | Fout koppelomvormer | There is an error on torque transducer 2 of a tool with multiple transducers. | Redundantiefout resetten | Log Display | Power Focus 6000 ToolsControl | Gereedschap |
2143 | Fout | Fout hoekomvormer | There is an error on torque transducer 2 of a tool with multiple transducers. | Redundantiefout resetten | Log Display | Power Focus 6000 ToolsControl | Gereedschap |
2144 | Waarschuwing | Tool Angle Transducer 2 Needs Calibration | Angle Transducer 2 needs calibration. | Gereedschap vereist motorafstelling | Log Conf Display | Flex Power Focus 6000 ToolsControl Power Focus 8 Synchronized tightening Power Focus 500 | Gereedschap |
2145 | Waarschuwing | Tool Angle Transducer 3 Needs Calibration | Angle Transducer 3 needs calibration. | Gereedschap vereist motorafstelling | Log Conf Display | Flex Power Focus 6000 ToolsControl Power Focus 8 Synchronized tightening Power Focus 500 | Gereedschap |
2146 | Fout | Tool Angle Transducer Error on Transducer 3 | Will be generated if tool reports transducer error from angle transducer 3. | Service the tool. | Log Conf Display | Flex Power Focus 6000 ToolsControl Power Focus 8 Synchronized tightening Power Focus 500 | Gereedschap |
2150 | Fout | Fout koppelomvormer Signal stuck at maximum level | Shunt check failed on torque transducer 1. Signal stuck at max level. | Service the tool. | Log Display | IxB XB | Gereedschap |
2151 | Fout | Fout koppelomvormer Signal stuck at minimum level | Shunt check failed on torque transducer 1. Signal stuck at min level. | Service the tool. | Log Display | IxB XB | Gereedschap |
2152 | Fout | Fout koppelomvormer Signal stuck at zero level | Shunt check failed on torque transducer 1. Signal stuck at zero level. | Service the tool. | Log Display | IxB XB | Gereedschap |
2153 | Fout | Fout koppelomvormer Signal exceeds maximum shunt value limit | Shunt check failed on torque transducer 1. Signal out of range. Below limit. | Service the tool. | Log Display | IxB XB | Gereedschap |
2154 | Fout | Fout koppelomvormer Signal below minimum shunt value limit | Shunt check failed on torque transducer 1. Signal out of range. Above limit. | Service the tool. | Log Display | IxB XB | Gereedschap |
2155 | Fout | Fout koppelomvormer Signal out of range since previous measurement | Shunt check failed on torque transducer 1. Signal out of range compared to last measurement. | Service the tool. | Log Display | IxB XB | Gereedschap |
2156 | Fout | Fout koppelomvormer Signal stuck at maximum level | Shunt check failed on torque transducer 2. Signal stuck at max level. | Service the tool. | Log Display | IxB XB | Gereedschap |
2157 | Fout | Fout koppelomvormer Signal stuck at minimum level | Shunt check failed on torque transducer 2. Signal stuck at min level. | Service the tool. | Log Display | IxB XB | Gereedschap |
2158 | Fout | Fout koppelomvormer Signal stuck at zero level | Shunt check failed on torque transducer 2. Signal stuck at zero level. | Service the tool. | Log Display | IxB XB | Gereedschap |
2159 | Fout | Fout koppelomvormer Signal exceeds maximum shunt value limit | Shunt check failed on torque transducer 2. Signal out of range. Below limit. | Service the tool. | Log Display | IxB XB | Gereedschap |
2160 | Fout | Fout koppelomvormer Signal below minimum shunt value limit | Shunt check failed on torque transducer 2. Signal out of range. Above limit. | Service the tool. | Log Display | IxB XB | Gereedschap |
2161 | Fout | Fout koppelomvormer Signal out of range since previous measurement | Shunt check failed on torque transducer 2. Signal out of range compared to last measurement. | Service the tool. | Log Display | IxB XB | Gereedschap |
2162 | Fout | Fout koppelomvormer Torque value too low | Detected value below limits on torque transducer. | Restart the tool. If the problem persists, service the tool. | Log Display Conf | Power Focus 6000 Power Focus 8 Flex Synchronized tightening ToolsControl | Gereedschap |
2163 | Fout | Fout koppelomvormer Torque value too high | Detected value above limits on torque transducer. | Restart the tool. If the problem persists, service the tool. | Log Display Conf | Power Focus 6000 Power Focus 8 Flex Synchronized tightening ToolsControl | Gereedschap |
2164 | Fout | Fout koppelomvormer Torque value too low | Detected value below limits on torque transducer 2. | Restart the tool. If the problem persists, service the tool. | Log Display Conf | Power Focus 6000 Power Focus 8 Flex Synchronized tightening ToolsControl | Gereedschap |
2165 | Fout | Fout koppelomvormer Torque value too high | Detected value above limits on torque transducer 2. | Restart the tool. If the problem persists, service the tool. | Log Display Conf | Power Focus 6000 Power Focus 8 Flex Synchronized tightening ToolsControl | Gereedschap |
2166 | Fout | Tool restarted after an unexpected internal software error. | Tool was restarted after an unexpected internal software error. | Service the tool if problem persists. | Log Display Conf | Power Focus 6000 Power Focus 8 Flex Synchronized tightening ToolsControl | Gereedschap |
2167 | Fout | Tool internal communication error on transducer module. | Tool internal communication error on transducer module. | Restart the tool. If the problem persists, service the tool. | Log Display Conf | Power Focus 6000 Power Focus 8 Flex Synchronized tightening ToolsControl | Gereedschap |
2168 | Fout | Tool internal communication error on transducer module 2. | Tool internal communication error on transducer module 2. | Restart the tool. If the problem persists, service the tool. | Log Display Conf | Power Focus 6000 Power Focus 8 Flex Synchronized tightening ToolsControl | Gereedschap |
2169 | Fout | Tool internal communication error with transducer module | Tool internal communication error with transducer module. | Restart the tool. If the problem persists, service the tool. | Log Display Conf | Power Focus 6000 Power Focus 8 Flex Synchronized tightening ToolsControl | Gereedschap |
2170 | Fout | Tool transducer module error - Voltage out of range (Vdda on board 2) | Vdda votage is out of range on board 2 of tool transducer module. | Restart the tool. If the problem persists, service the tool. | Log Display Conf | Power Focus 6000 Power Focus 8 Flex Synchronized tightening ToolsControl | Gereedschap |
2171 | Fout | Tool transducer module 2 error - Voltage out of range (Torque) | Torque supply voltage is out of range on torque transducer module 2. | Restart the tool. If the problem persists, service the tool. | Log Display Conf | Power Focus 6000 Power Focus 8 Flex Synchronized tightening ToolsControl | Gereedschap |
2174 | Fout | Tool transducer module error - Voltage out of range (Vdda on board 1) | Vdda votage is out of range on board 1 of tool transducer module. | Restart the tool. If the problem persists, service the tool. | Log Display Conf | Power Focus 6000 Power Focus 8 Flex Synchronized tightening ToolsControl | Gereedschap |
2175 | Fout | Tool transducer module error - CPU temperature high on board 1 | CPU temperature is high on board 1 of torque transducer module. | Wait until tool temperature has been reduced. If the problem persists, service the tool. | Log Display Conf | Power Focus 6000 Power Focus 8 Flex Synchronized tightening ToolsControl | Gereedschap |
2176 | Fout | Tool transducer module error - CPU temperature high on board 2 | CPU temperature is high on board 2 of torque transducer module. | Wait until tool temperature has been reduced. If the problem persists, service the tool. | Log Display Conf | Power Focus 6000 Power Focus 8 Flex Synchronized tightening ToolsControl | Gereedschap |
2177 | Fout | Tool torque transducer production calibration missing. | Production calibration parameters are missing on torque transducer module. | Restart the tool. If the problem persists, service the tool. | Log Display Conf | Power Focus 6000 Power Focus 8 Flex Synchronized tightening ToolsControl | Gereedschap |
2178 | Fout | Tool transducer module error - Voltage out of range (Torque) | Torque supply voltage is out of range on torque transducer module. | Restart the tool. If the problem persists, service the tool. | Log Display Conf | Power Focus 6000 Power Focus 8 Flex Synchronized tightening ToolsControl | Gereedschap |
2179 | Fout | Tool transducer module 2 error - Voltage out of range (Vdda on board 1) | Vdda votage is out of range on board 1 of tool transducer module 2. | Restart the tool. If the problem persists, service the tool. | Log Display Conf | Power Focus 6000 Power Focus 8 Flex Synchronized tightening ToolsControl | Gereedschap |
2180 | Fout | Tool transducer module 2 error - CPU temperature high on board 1 | CPU temperature is high on board 1 of torque transducer module 2. | Wait until tool temperature has been reduced. If the problem persists, service the tool. | Log Display Conf | Power Focus 6000 Power Focus 8 Flex Synchronized tightening ToolsControl | Gereedschap |
2181 | Fout | Tool transducer module 2 error - CPU temperature high on board 2 | CPU temperature is high on board 2 of torque transducer module 2. | Wait until tool temperature has been reduced. If the problem persists, service the tool. | Log Display Conf | Power Focus 6000 Power Focus 8 Flex Synchronized tightening ToolsControl | Gereedschap |
2182 | Fout | Tool torque transducer 2 production calibration missing. | Production calibration parameters are missing on torque transducer module 2. | Restart the tool. If the problem persists, service the tool. | Log Display Conf | Power Focus 6000 Power Focus 8 Flex Synchronized tightening ToolsControl | Gereedschap |
2183 | Fout | Tool transducer module 2 error - Voltage out of range (Vdda on board 2) | Vdda votage is out of range on board 2 of tool transducer module 2 | Restart the tool. If the problem persists, service the tool. | Log Display Conf | Power Focus 6000 Power Focus 8 Flex Synchronized tightening ToolsControl | Gereedschap |
2200 | Fout | IAM overcurrent occurred | IAM (SD-card) overcurrent on main board. | Service the tool. | Log Display Ack Conf | IxB | Gereedschap |
2201 | Fout | System radio module overcurrent occurred | Radio overcurrent on main board. | Service the tool. | Log Display Ack Conf | IxB | Gereedschap |
2202 | Fout | Tool HMI overcurrent occurred | Tool HMI overcurrent was detected. | Service the tool. Replace tool HMI. | Log Display Ack Conf | IxB | Gereedschap |
2203 | Fout | Tool front light overcurrent occurred | Tool front light overcurrent was detected | Service the tool. Replace tool front light. | Log Display Ack Conf | IxB | Gereedschap |
2204 | Fout | Accessory bus overcurrent occurred | Accessory bus overcurrent was detected. | Service the tool. Replace accessory bus. | Log Display Ack Conf | IxB | Gereedschap |
2205 | Fout | Main USB bus overcurrent occurred | USB overcurrent on main board. | Disconnect connected USB equipment. If the event persists, service the tool. | Log Display Ack Conf | IxB | Gereedschap |
2206 | Fout | Auxiliary USB bus overcurrent occurred | Accessory USB overcurrent on main board. | Disconnect connected USB equipment. If the event persists, service the tool. | Log Display Ack Conf | IxB | Gereedschap |
2207 | Fout | Vibrator overcurrent occurred | Vibrator overcurrent was detected. | Service the tool. Replace the vibrator. | Log Display Ack Conf | IxB | Gereedschap |
2208 | Waarschuwing | System CPU temperature high | System CPU temperature high. | Wait until tool temperature has been reduced. | Log Display Conf | IxB XB | Gereedschap |
2209 | Fout | System CPU temperature critical | System CPU temperature critical. | Wait until tool temperature has been reduced. | Log Display Conf | IxB XB | Gereedschap |
2210 | Fout | Unsupported power source: tightening not permitted | Battery with too low voltage attached to the tool. | Attach battery with higher voltage to the tool. | Log Display Ack Conf | IxB | Gereedschap |
2217 | Info | Running on backup battery | Running on backup battery. | Log | IxB | Gereedschap | |
2218 | Info | Battery connected | Battery connected or controller/tool started. | Log | IxB | Gereedschap | |
2219 | Info | Power source: unknown | Unknown power source connected or controller/tool started with unknown power source. | Log | IxB | Gereedschap | |
2220 | Fout | Gereedschap storing in ventilatorspanning | Applies to IPB-P. | Service the tool. | Log Display Ack | IxB | Gereedschap |
2221 | Waarschuwing | Battery overheated | Battery temperature is too high. | Change battery and let overheated battery cool down. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 ToolsControl | Gereedschap |
2222 | Waarschuwing | Gebruik beperkt vanwege hoge gereedschapstemperatuur. | Battery temperature is too high. | Change battery and let overheated battery cool down. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 ToolsControl | Gereedschap |
2223 | Fout | Front LED is not available | When the tool boots up, if the front LED is not detected, this event will be triggered. | Fix the front light or the front light cable connection. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 | Controller and Tool |
2224 | Fout | Front LED color is not available | When the tool boots up, if the front LED color is not detected, this event will be triggered. | Fix the front light color or the front light cable connection | Log Display Conf | IxB Power Focus 6000 Power Focus 8 | Controller and Tool |
2225 | Fout | RHMI buttons are not available | When the tool boots up, if the RHMI buttons are not detected, an event will be triggered. | Fix the RHMI buttons. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 | Controller and Tool |
2226 | Fout | LED ring is not available | When the tool boots up, if the LED ring is not detected, an event will be triggered. | Fix the back ring lights or the back ring light connection. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 | Controller and Tool |
2227 | Fout | Fan is not available | When the tool boots up, if the fan is not detected, an event will be triggered. | Fix the fan. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 | Controller and Tool |
2228 | Fout | RRE board is not available | When the tool boots up, if the tool board interface is not detected, an event will be triggered. | Fix the tool board interface. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 | Controller and Tool |
2229 | Waarschuwing | Gereedschap reservebatterij gebruikt | Gereedschap reservebatterij gebruikt | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Gereedschap | |
2230 | Info | Tool Backup battery fully charged | Tool backup battery is fully charged. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Gereedschap | |
2231 | Waarschuwing | Gereedschap reservebatterij gebruikt | Gereedschap reservebatterij gebruikt | Het plaatsen van een batterij | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Gereedschap |
2232 | Waarschuwing | Gereedschap reservebatterij gebruikt | Gereedschap reservebatterij gebruikt | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Gereedschap | |
2233 | Waarschuwing | Tool restricted battery support | Tool can not perform on its configured max torque or speed with this type of battery. | Replace battery with version specified for this type of tool. | Log Conf Display Ack | IxB | Gereedschap |
2234 | Waarschuwing | Poor angle signal quality | Motortune required. If the event pops up shortly after a motor tune, the tool needs service. | Motor tune tool. | Log Conf Display Ack | IxB | Gereedschap |
2300 | Fout | Tool main board error - Voltage out of range (Torque) | Restart the tool. If the error persist, service the tool an look for lose connections in the cable connectors. Inspect any possible damage in the cables. | Log Display Ack | IxB | Gereedschap | |
2301 | Fout | Tool main board error - Voltage out of range (Analog) | Restart the tool. If the error persist, service the tool an look for lose connections in the cable connectors. Inspect any possible damage in the cables. | Log Display Ack | IxB | Gereedschap | |
2302 | Fout | Tool main board error - Voltage out of range (MCU Vdd) | Restart the tool. If the error persist, service the tool an look for lose connections in the cable connectors. Inspect any possible damage in the cables. | Log Display Ack | IxB | Gereedschap | |
2303 | Fout | Tool main board error - Voltage out of range (Step up) | Restart the tool. If the error persist, service the tool an look for lose connections in the cable connectors. Inspect any possible damage in the cables. | Log Display Ack | IxB | Gereedschap | |
2304 | Fout | Tool main board error - Voltage out of range (UPS) | Restart the tool. If the error persist, service the tool an look for lose connections in the cable connectors. Inspect any possible damage in the cables. | Log Display Ack | IxB | Gereedschap | |
2305 | Fout | Tool main board error - Voltage out of range (Tool power) | Restart the tool. If the error persist, service the tool an look for lose connections in the cable connectors. Inspect any possible damage in the cables. | Log Display Ack | IxB XB | Gereedschap | |
2306 | Fout | Tool main board error - Voltage out of range (Vdd) | Restart the tool. If the error persist, service the tool an look for lose connections in the cable connectors. Inspect any possible damage in the cables. | Log Display Ack | IxB XB | Gereedschap | |
2307 | Fout | Tool main board error - Hardware failure (IMU) | Service the tool. | Log Display Ack | IxB | Gereedschap | |
2330 | Fout | Gereedschap voedingsmodule fout Voltage high (Tool power) | Tool power voltage on power module out of range. Too high. | Service the tool. | Log Conf Display Ack | IxB | Gereedschap |
2331 | Fout | Tool power module error - Voltage low (Reference) | Service the tool. | Log Display Ack | IxB | Gereedschap | |
2332 | Fout | Tool power module error - Voltage high (Reference) | Service the tool. | Log Display Ack | IxB | Gereedschap | |
2333 | Fout | Tool power module error - Voltage low (UPS) | Service the tool. | Log Display Ack | IxB | Gereedschap | |
2334 | Fout | Tool power module error - Voltage high (UPS) | Service the tool. | Log Display Ack | IxB | Gereedschap | |
2335 | Fout | Tool power module error - Voltage low (Backup domain) | Service the tool. | Log Display Ack | IxB | Gereedschap | |
2336 | Fout | Tool power module error - Voltage high (Backup domain) | Service the tool. | Log Display Ack | IxB | Gereedschap | |
2360 | Waarschuwing | Motor tune failure: Generic error | Generic motor tune error. | Retry motor tuning. If the error persists, service the tool. | Log Conf | IxB XB | Gereedschap |
2361 | Waarschuwing | Motor tune failure: Fout starten met afstandsbediening | Generic motor tune start error. | Retry motor tuning. If the error persists, service the tool. | Log Conf | IxB XB | Gereedschap |
2362 | Waarschuwing | Motor tune failure: Aandrijving niet ingeschakeld | Motor tune could not start drive. | Retry motor tuning. If the error persists, service the tool. | Log Conf | IxB XB | Gereedschap |
2363 | Waarschuwing | Motor tune failure: Illegal rotor movement detected | Unexpected motor movement detected during motor tune. | Make sure the tool is not disturbed during motor tuning. Retry motor tuning. If the error persists, service the tool. | Log Conf | IxB XB | Gereedschap |
2364 | Waarschuwing | Motor tune failure: Torque too high | Torque detected during motor tune. | Remove any torque load from the tool and retry motor tuning. If the error persists, service the tool. | Log Conf | IxB XB | Gereedschap |
2365 | Waarschuwing | Motor tune failure: Rotor not moved | Motor did not move during motor tune. | Make sure the tool can rotate freely and retry motor tuning. If the error persists, service the tool. | Log Conf | IxB XB | Gereedschap |
2366 | Waarschuwing | Motor tune failure: Tuning speed not reached | Motor speed was too low during motor tune. | Retry motor tuning. If the error persists, service the tool. | Log Conf | IxB XB | Gereedschap |
2367 | Waarschuwing | Motor tune failure: Motor current response error | Motor current error during motor tune. | Retry motor tuning. If the error persists, service the tool. | Log Conf | IxB XB | Gereedschap |
2368 | Waarschuwing | Motor tune failure: Motorstroom overschreden | No motor current during motor tune. | Retry motor tuning. If the error persists, service the tool. | Log Conf | IxB XB | Gereedschap |
2369 | Waarschuwing | Motor tune failure: No sin/cos signal | Angle signal stuck at zero during motor tune. | Retry motor tuning. If the error persists, service the tool. | Log Conf | IxB XB | Gereedschap |
2370 | Waarschuwing | Motor tune failure: Sin/cos signal error | Angle signal outside of limits during motor tune. | Retry motor tuning. If the error persists, service the tool. | Log Conf | IxB XB | Gereedschap |
2371 | Waarschuwing | Motor tune failure: Broken angle sensor | Motor alignment during motor tune failed. | Retry motor tuning. If the error persists, service the tool. | Log Conf | IxB XB | Gereedschap |
2372 | Waarschuwing | Motor tune failure: Fout communicatie aandrijving | Power module timeout during motor tune. | Retry motor tuning. If the error persists, service the tool. | Log Conf Display | IxB XB | Gereedschap |
2373 | Waarschuwing | Motor tune failure: Invalid parameter data | Motor tune parameters not set. Fout in modusconfiguratie | Retry motor tuning. If the error persists, service the tool. | Log Conf | IxB XB | Gereedschap |
2374 | Waarschuwing | Motor tune failure: Software error | Gereedschap interne softwarefout | Retry motor tuning. If the error persists, service the tool. | Log Conf | IxB XB | Gereedschap |
2375 | Waarschuwing | Motor tune failure: Activering verloren gegaan | Motor tune aborted. | Retry motor tuning and let the sequence finish without interruption. If the event persists, service the tool. | Log Conf | IxB XB | Gereedschap |
2376 | Waarschuwing | Motor tune failure: Blocked due to previous error | Motor tune blocked due to previous error. | Resolve the previous motor tuning error and run motor tuning again. Service the tool if the block persists. | Log Conf | IxB XB | Gereedschap |
2377 | Waarschuwing | Afstellen met open einde geslaagd | Open end tuning timed Out. | Resume operation after temperature drops, service if recurring. | Log Conf | Power Focus 6000 Power Focus 8 IxB | Controller and Tool |
2378 | Fout | Motor tune failure: Unknown angle error | Service the tool. | Log | IxB | Gereedschap | |
2379 | Fout | Motor tune failure: Angle sample failed | Service the tool. | Log | IxB | Gereedschap | |
2380 | Fout | Motor tune failure: Angle accumulation | Service the tool. | Log | IxB | Gereedschap | |
2381 | Fout | Motor tune failure: Angle signal inverted | Service the tool. | Log | IxB | Gereedschap | |
2382 | Fout | Motor tune failure: Angle signal stuck | Service the tool. | Log | IxB | Gereedschap | |
2383 | Fout | Motor tune failure: Angle signal different to RRE | Angle signal different to RRE (motor angle). | Service the tool. | IxB | Gereedschap | |
2500 | Fout | Tensioner puller bar max number | Tensioner puller bar must be replaced. System is locked for usage. Pressure can only be released. | Send the tensioner to service organization for replacement of the puller bar. | Log Display Ack | Power Focus 500 | Gereedschap |
2501 | Fout | Pump motor protection alarm | The pump motor protection has stopped the motor. The system must stop. If the system is under pressure, it needs manual actions to release pressure. | Schakel het gereedschap uit. If under pressure, mechanically release the pressure and send the pump to service. | Log Display Ack | Power Focus 500 | Gereedschap |
2502 | Fout | Pump motor oil level low alarm | The pump motor oil level is low which has stopped the motor. If the system is under pressure, it needs manual actions to release pressure. | Schakel het gereedschap uit. If under pressure, mechanically release the pressure and top up oil. | Log Display Ack | Power Focus 500 | Gereedschap |
2503 | Fout | Pump motor oil temperature high alarm | The pump motor oil temperature is high. | Turn off the system and wait for the oil to cool down. | Log Display Ack | Power Focus 500 | Gereedschap |
2504 | Fout | Tensioner pressure sensor alarm | Failure in the pressure sensor electronics of the tensioner. No pressure can be read nor reported to the system. | Schakel het gereedschap uit. If under pressure, mechanically release the pressure and send the tensioner to service. | Log Display Ack | Power Focus 500 | Gereedschap |
2505 | Fout | Pump pressure sensor alarm | Failure in the pressure sensor electronics of the pump. No pressure can be read nor reported to the system. | Schakel het gereedschap uit. If under pressure, mechanically release the pressure and send the pump to service. | Log Display Ack | Power Focus 500 | Gereedschap |
2506 | Fout | Unexpected clockwise rotation detected | A clockwise nut rotation while waiting for pressure release after completed tensioning. The result is invalidated. | Release pressure and tension the nut again. | Log Display Conf | Power Focus 500 | Gereedschap |
2507 | Fout | Unexpected counter clockwise rotation detected | A counter clockwise nut rotation while waiting for pressure release after completed tensioning. The result is invalidated. | Release pressure and tension the nut again. | Log Display Conf | Power Focus 500 | Gereedschap |
2508 | Fout | Pump or tensioner pressure sensor failure | Too large difference between the pressure sensor readings in the pump and the tensioner. Pressurization is halted. | Problem in the hydraulics or the calibration of the pressure sensors. Schakel het systeem in en probeer het opnieuw. Neem voor meer informatie contact op met uw lokale Atlas Copco-verkoopvertegenwoordiger. | Log Display Ack | Power Focus 500 | Gereedschap |
2509 | Fout | Tensioner pressure sensor failure or hydraulic hose failure | The tensioner's pressure sensor indicates no pressure but the pump's sensor reads a pressure increase. Pressurization is halted. | Problem in the hydraulics or the calibration of the pressure sensors. Schakel het systeem in en probeer het opnieuw. Neem voor meer informatie contact op met uw lokale Atlas Copco-verkoopvertegenwoordiger. | Log Display Ack | Power Focus 500 | Gereedschap |
2510 | Fout | Set custom ID failed | Setting custom ID failed. | Restart the system and check the connected devices. If Custom ID for the unit is wrong, redo the setting. | Log Display Ack | Power Focus 500 | Gereedschap |
2511 | Info | Custom ID is set | Setting custom ID succeeded. | Log Display Ack | Power Focus 500 | Gereedschap | |
2512 | Waarschuwing | Malformed Barcode string, ignored | The scanned string could not be parsed as a tower data bar code. | Scan a proper tower data qr code or scan tower section id. | Log Display Ack | Power Focus 500 | Gereedschap |
2513 | Fout | No pump pressure detected | The system is trying to pressurize but no pressure increase is registered in the pump. Possible cause is incorrect phase order in the three phase connector. | Power off the system and reverse the phases of the power connector. | Log Display Ack | Power Focus 500 | Gereedschap |
2514 | Waarschuwing | Tensioner overtorque alarm | Too high torque is applied to the click wrench. This causes damage to the torque sensor. | Relax the torque. | Log | Power Focus 500 | Gereedschap |
2515 | Waarschuwing | Tensioner overpressure alarm | The pressure in the tensioner is too high. | Let the pressure drop, or release the pressure. Check the hydraulic pressure parameters. | Log | Power Focus 500 | Gereedschap |
2516 | Waarschuwing | Unexpected Pump or Tensioner firmware | Unexpected Pump or Tensioner firmware version detected, restart system. If the problem persists, the system may be possible to run, but carefully observe any unexpected behaviour. | Power cycle system | Log Display Ack | Power Focus 500 | Gereedschap |
2517 | Fout | Incompatible Pump or Tensioner firmware version, restart system. The system cannot run. | Incompatible Pump or Tensioner firmware version, restart system. The system cannot run. | Restart system, if this doesn’t help replace the failing unit. Check connected devices to see which one has not connected. | Log Display Ack | Power Focus 500 | Gereedschap |
2518 | Fout | Physical safety signal failed. | Safety signal from the hand controller has not reached the pump | Check the cable connected to the tensioner If the event re occurs contact service | Log Display Ack | Power Focus 500 | Gereedschap |
2519 | Fout | System entered fail safe mode | Fail safe mode activated | User acknowledgment required | Log Display Ack | Power Focus 500 | Gereedschap |
2520 | Fout | System exits fail safe mode | Fail safe mode deactivated | System returns to normal function | Log Display Ack | Power Focus 500 | Gereedschap |
2523 | Fout | Communication lost with the tensioner | Communication lost with the tensioner | Check the cable connected to the tensioner Event can occur when the system is powered off | Log Display Ack | Power Focus 500 | Gereedschap |
2524 | Fout | Communication lost with the pump | Communication lost with the pump | . Check the cables are connected Event can occur when the system is powered off | Log Display Ack | Power Focus 500 | Gereedschap |
2525 | Fout | Action requested from the hand controller is not performed by the pump | Action requested from the hand controller is not performed by the pump | Try again If this event occurs often contact service. | Log Display Ack | Power Focus 500 | Gereedschap |
2800 | Fout | There is an error on the clutch sensor | Check sensor and clutch assembly | If this event occurs often contact service. | Log Display Ack | Power Focus 6000 Power Focus 8 | Gereedschap |
2801 | Fout | Triggered when clutch settings alarm is enabled in settings and the current time is greater than next clutch settings date | Indicates that clutch settings of tool is needed | If this event occurs often contact service. | Log Display Ack | Power Focus 6000 Power Focus 8 | Gereedschap |
3000 | Fout | Interne softwarefout controller | Software error in the controller. | Neem contact op met de serviceafdeling | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Controller |
3001 | Fout | Batterij controllerklok leeg | Internal battery is getting close to end of life. | Replace battery. | Log Display Ack Conf | Flex Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 | Controller, Drive and Synchronized tightening |
3002 | Fout | Gereedschap interne softwarefout | Software error in the drive. | Neem contact op met de serviceafdeling | Log Display Conf | Flex Synchronized tightening | Aandrijving |
3010 | Waarschuwing | System Overheated | The controller is overheated. | Cool down. | Log Display Conf | Power Focus 6000 Power Focus 8 Power Focus 500 | Controller, Drive and Synchronized tightening |
3011 | Waarschuwing | Drive Overheated Controller Hardware | Cool down. | Log Display Conf | Flex ToolsControl | Controller, Drive and Synchronized tightening | |
3013 | Waarschuwing | Gebruik beperkt vanwege hoge controllertemperatuur. | Temperature limit value has been reached. Tightening has been inhibited to reduce risk for controller shutting down due to overheating. | Wait until controller temperature has been reduced. | Log Display Conf | Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 | Controller, Drive and Synchronized tightening |
3020 | Waarschuwing | Hardwarestoring controller | Log Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 | Controller, Drive and Synchronized tightening | ||
3021 | Waarschuwing | Probleem met systeemspanning | DC voltage too high or too low. | Log Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 | Controller, Drive and Synchronized tightening | |
3022 | Waarschuwing | Controller Voltage Problem: AC Input Voltage Too High | DC voltage too high or too low. | Fix the input voltage. | Log Display | Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 | Controller, Drive and Synchronized tightening |
3023 | Waarschuwing | Controller Voltage Problem: AC Input Voltage Too Low | DC voltage too high or too low. | Fix the input voltage. | Log Display | Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 | Controller, Drive and Synchronized tightening |
3024 | Waarschuwing | Drive Voltage Problem: AC Input Voltage Too High | DC voltage too high or too low. | Fix the input voltage. | Log Display | Flex ToolsControl | Controller, Drive and Synchronized tightening |
3025 | Waarschuwing | Drive Voltage Problem: AC Input Voltage Too Low | DC voltage too high or too low. | Fix the input voltage. | Log Display | Flex ToolsControl | Controller, Drive and Synchronized tightening |
3026 | Info | Max number of IxB Connect tools already connected. | Indicates that the number of IxB Connect tools connected to the controller has reached the max. allowed connected tools. | Log | ToolsControl | Controller and Tool | |
3027 | Info | The access point lost Bluetooth connection | Bluetooth connection to the tool has been lost. | Bluetooth link between tool and controller was interrupted. Check distance, interference, and Bluetooth settings. Reconnect or re-pair the tool. | Log Display Conf | Power Focus 6000 Power Focus 8 IxB | Controller and Tool |
3028 | Info | The access point lost network connection | Connection to the wireless access point has been lost. | Wireless access point connection lost. Verify AP availability, signal strength, and credentials. Restore Wi-Fi connection. | Log Display Conf | Power Focus 6000 Power Focus 8 IxB | Controller and Tool |
3029 | Info | The client lost network connection | The tool has lost the network connection by either leaving the network coverage or due to another cause. | Troubleshoot by checking the roaming threshold and reduce the selected channel numbers to less than 24 to make sure roaming is enabled. | Log Display Conf Ack | IxB | Controller and Tool |
3030 | Fout | IP-adresconflict met ander systeem in netwerk | The set IP address is in use by another device on the same network. | Change IP address on one of the devices. | Log Display Conf | Flex Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 Power Focus 500 | Controller, Drive and Synchronized tightening |
3031 | Info | Netwerkkabel losgekoppeld | The carrier of the factory port is lost (cable disconnected). | Controleer de luchtaansluiting. | Log Display Conf | Flex Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 | Controller, Drive and Synchronized tightening |
3032 | Info | Koppelen gestart | Tool pairing started. | Log Display Conf | Power Focus 6000 Power Focus 8 Power Focus 500 | Controller, Drive and Synchronized tightening | |
3033 | Info | Koppelen geslaagd | Tool pairing successful. | Log Display Conf | Power Focus 6000 Power Focus 8 Power Focus 500 | Controller, Drive and Synchronized tightening | |
3034 | Info | Koppelen mislukt: No Tool Found | The controller found no tool to pair with when scanning for radio peers. | Set the tool in pairing mode and try again. | Log Display Conf | Power Focus 6000 Power Focus 8 Power Focus 500 | Controller, Drive and Synchronized tightening |
3035 | Fout | Koppelen mislukt: Meer dan één gereedschap gevonden | The controller found more than one tool when scanning for radio peers. | Ensure that only one tool is in pairing mode when starting the pairing mode on the controller. | Log Display Conf | Power Focus 6000 Power Focus 8 Power Focus 500 | Controller, Drive and Synchronized tightening |
3036 | Fout | Koppelen mislukt: Communicatiefout | The controller experienced a loss of connection, an unexpected answer or timeout during the pairing process. | Try to perform pairing one more time. If it fails again, service the tool. | Log Display Conf | Power Focus 6000 Power Focus 8 Power Focus 500 | Controller, Drive and Synchronized tightening |
3037 | Info | Koppelen mislukt: Gereedschapssleuf is vol | Clear one tool slot. | Log Display Conf | Power Focus 6000 Power Focus 8 Power Focus 500 | Controller, Drive and Synchronized tightening | |
3040 | Waarschuwing | Noodstop | Drive disabled due to emergency stop. | Reset emergency stop. | Log Display Conf | Flex Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Controller, Drive and Synchronized tightening |
3045 | Info | Toolsnet server communication failed. Please check the Server Connections tab of Protocol Status dialog for more information. | Verbinding met de server mislukt. | Verbinding met de server mislukt. Check network connectivity and server status. Restore server connection. | Log Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 Power Focus 500 | Controller and Tool |
3046 | Info | Toolsnet server communication established | Communication with the ToolsNet server is restored. | ToolsNet server communication restored. Controleer datacommunicatie Geen actie vereist. | Log Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 Power Focus 500 | Controller and Tool |
3047 | Info | Toolstalk server communication failed. Please check the Server Connections tab of Protocol Status dialog for more information. | Verbinding met de server mislukt. | Verbinding met server verloren Check network and ToolTalk service. Restore server communication. | Log Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 | Controller and Tool |
3048 | Info | Toolstalk server communication established | Communication with the ToolTalk server is restored. | ToolTalk server communication restored. Verify normal data exchange. Geen actie vereist. | Log Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 | Controller and Tool |
3050 | Info | System Clock Updated | System clock has been updated. | Log Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 Power Focus 500 | Controller, Drive and Synchronized tightening | |
3051 | Fout | System Clock Error | Wrong time read from hardware Real Time Clock (RTC). | Vervang de RTC-batterij. | Log Display Ack Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 Power Focus 500 | Controller, Drive and Synchronized tightening |
3052 | Waarschuwing | Fout in configuratie externe start | Mismatch between HW and SW remote start configuration. | Verify that HW dip switch matches the selected start source. | Log Display Conf | Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Controller, Drive and Synchronized tightening |
3053 | Info | Aandrijving aangesloten | Synchronized tightening drive has been connected. | Log Display | Flex Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Controller, Drive and Synchronized tightening | |
3054 | Info | Aandrijving losgekoppeld | Drive disconnected from controller. | Check cabling and power-supply for externally connected drives or replace the controller. | Log Display | Flex Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Controller, Drive and Synchronized tightening |
3055 | Waarschuwing | Fout in modusconfiguratie | Generated when selected mode is configured wrongly. E.g. configuring two bolts with the same bolt number or the same channel, incomplete mode configuration. | Check ToolsTalk 2 for mode configuration error. | Log Display | Flex Synchronized tightening | Controller, Drive and Synchronized tightening |
3056 | Waarschuwing | Unable to Start: Tool Or Drive Is Missing | Generated when a used channel is missing a drive or tool. | Verify Channel Menu on the HMI. Connect missing drive or tool. | Log Display | Flex Synchronized tightening | Controller, Drive and Synchronized tightening |
3057 | Info | Unable to Start: Channel Is Already In Use | Generated when a needed channel has been allocated to another virtual station. | Log Display | Flex | Controller, Drive and Synchronized tightening | |
3058 | Info | No Mode Selected | Select mode. | Log Display | Flex Synchronized tightening | Controller, Drive and Synchronized tightening | |
3059 | Waarschuwing | Kan niet verbinden met Atlas Copco-licentiebeheer | Indicates that the controller failed to connect to the local license manager to get licenses. | Verify the local network. If it fails again, service the controller. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Controller, Drive and Synchronized tightening |
3060 | Fout | Aantal licenties voor virtuele stations is overschreden | Virtual Station license greater than available licenses. | Update licenses or Virtual Station configuration. | Log Display Ack | ToolsControl | Controller |
3061 | Waarschuwing | Unable To Start: Enable Signal Is Low | Ensure the signal "Enable Operation" is set to high before tightening is started. | Log Display | Flex Synchronized tightening | Controller, Drive and Synchronized tightening | |
3062 | Waarschuwing | Unable To Start: Stop Signal Is High | Ensure the signal "Enable Operation" is set to low before tightening is started. | Log Display | Flex Synchronized tightening | Controller, Drive and Synchronized tightening | |
3063 | Waarschuwing | Unable To Start: All Channels Inhibited | All channels have been set inhibited, so no tightening can be started. | Set at least one channel to not be inhibited. | Log Display | Flex Synchronized tightening | Controller, Drive and Synchronized tightening |
3064 | Waarschuwing | Carrier Number Faulty | A FlexCarrier hex switch is set to zero. | Turn the switch to a non-zero value. | Log Display | Flex | Controller, Drive and Synchronized tightening |
3065 | Waarschuwing | Carrier E-Stop Configuration Plug Wrong Type Or Missing | A Carrier is missing its E-stop configuration plug, or the plug type is wrong. | Insert correct plug type. | Log Display | Flex | Controller, Drive and Synchronized tightening |
3066 | Waarschuwing | Carrier Voltage Inlet: No 3-Phase AC | Ensure the 3-phase power to the carrier is within acceptable limits and fully functional. Ensure the 3-phase cables are in good condition and properly connected. | Log Display | Flex | Controller, Drive and Synchronized tightening | |
3067 | Waarschuwing | Carrier Voltage Inlet: One AC Phase Missing | Ensure the 3-phase power to the carrier is within acceptable limits and fully functional. Ensure the 3-phase cables are in good condition and properly connected. | Log Display | Flex | Controller, Drive and Synchronized tightening | |
3068 | Waarschuwing | Carrier: Drager, interne 24 VDC voedingseenheid defect | Service the carrier. | Log Display | Flex | Controller, Drive and Synchronized tightening | |
3069 | Waarschuwing | Drager 24V uitgang uitgeschakeld wegens overstroom | Reset the system. | Log Display | Flex | Controller, Drive and Synchronized tightening | |
3070 | Waarschuwing | Drager, hardwarefout in PF6 FlexControl-kabel UIT | Reset the system. | Log Display | Flex | Controller, Drive and Synchronized tightening | |
3071 | Waarschuwing | Drager, hardwarefout in PF6 FlexControl-kabel IN | Reset the system. | Log Display | Flex | Controller, Drive and Synchronized tightening | |
3072 | Waarschuwing | Noodstop 24 VDC stroomstoring door kortsluiting | Service the carrier. | Log Display | Flex | Controller, Drive and Synchronized tightening | |
3073 | Waarschuwing | Unable To Start: System Is Emergency Stopped | When allocating multiple spindles, this event is invoked by "preStartCheckFailed" due to emergency stop. | Reset the emergency stop. | Log Display | Flex Synchronized tightening | Controller, Drive and Synchronized tightening |
3074 | Waarschuwing | Drager oververhit | Cool down. | Log Display | Flex | Controller, Drive and Synchronized tightening | |
3075 | Waarschuwing | Temperatuur drager OK | Log Display | Flex | Controller, Drive and Synchronized tightening | ||
3076 | Waarschuwing | Carrier: Drager, interne 24 VDC voeding overbelast | Current output from internal PSU is too high. | Disconnect other carriers that are powered from the PSU. Disconnect any external equipment using 24 VDC. | Log Display | Flex | Controller, Drive and Synchronized tightening |
3077 | Waarschuwing | Carrier: Drager, interne 24 VDC voeding overspanning | Voltage output from internal PSU is too high. | Replace the carrier. | Log Display | Flex | Controller, Drive and Synchronized tightening |
3078 | Waarschuwing | Carrier: Drager, interne 24 VDC voeding onderspanning | Voltage output from internal PSU is too low. | Replace the carrier. | Log Display | Flex | Controller, Drive and Synchronized tightening |
3079 | Waarschuwing | External Supply To Carrier: 24 VDC Over Voltage | Backup input voltage is more than 27 VDC. | Adjust the backup input voltage. | Log Display | Flex | Controller, Drive and Synchronized tightening |
3080 | Waarschuwing | External Supply To Carrier: 24 VDC Under Voltage | Backup input voltage is less than 19 VDC. | Adjust the backup input voltage. | Log Display | Flex | Controller, Drive and Synchronized tightening |
3081 | Waarschuwing | Carrier Voltage Inlet: 3-Phase AC Over Voltage | Input voltage is too high. | Lower input voltage: must be 400 VAC or 480 VAC. | Log Display | Flex | Controller, Drive and Synchronized tightening |
3082 | Waarschuwing | Carrier Voltage Inlet: 3-Phase AC Under Voltage | Input voltage is too low. | Higher input voltage: must be 400 VAC or 480 VAC. | Log Display | Flex | Controller, Drive and Synchronized tightening |
3083 | Fout | Onjuiste firmware Anybus/Profisafe-module | Update the firmware in the anybus module to the latest version. | Log Display | Flex Power Focus 6000 Power Focus 8 Synchronized tightening | Controller, Drive and Synchronized tightening | |
3084 | Fout | Soft-PLC runtimefout. | eCLR has terminated in an uncontrolled way. | Log Display Conf | Flex Power Focus 6000 Power Focus 8 Synchronized tightening | Controller, Drive and Synchronized tightening | |
3085 | Waarschuwing | Carrier: Drager, ventilatormodule buiten werking | Replace fan module. | Log Display | Flex | Controller, Drive and Synchronized tightening | |
3086 | Waarschuwing | Carrier: Drager, ventilatormodule gedeeltelijk buiten werking | Replace fan module. | Log Display | Flex | Controller, Drive and Synchronized tightening | |
3087 | Waarschuwing | Carrier: Drager, ventilatormodule buiten werking | Replace fan module. | Log Display | Flex | Controller, Drive and Synchronized tightening | |
3088 | Waarschuwing | Carrier: Drager, linker ventilatormodule gedeeltelijk buiten werking | Replace fan module. | Log Display | Flex | Controller, Drive and Synchronized tightening | |
3089 | Waarschuwing | Carrier: Drager, ventilatormodule buiten werking | Replace fan module. | Log Display | Flex | Controller, Drive and Synchronized tightening | |
3090 | Waarschuwing | Carrier: Drager, rechter ventilatormodule gedeeltelijk buiten werking | Replace fan module. | Log Display | Flex | Controller, Drive and Synchronized tightening | |
3091 | Info | Adresconflict synchronisatieleden | Generated when two or more sync members are configured to the same channel. | Reconfigure the colliding sync member to have a unique or different channel that has not been allocated to another sync member. | Log Conf Display Ack | Power Focus 8 Synchronized tightening ToolsControl | Controller, Drive and Synchronized tightening |
3093 | Waarschuwing | Digital input received before the trigger is pressed. | Indicates that something went wrong with setup. | Log Conf Display Ack | Power Focus 8 Synchronized tightening ToolsControl | Controller, Drive and Synchronized tightening | |
3095 | Waarschuwing | WiFi Signal Strength Low | The wireless network signal strength is below the value set in setting "Warn on signal strength below (dBm)". | Conf | IxB | Controller and Tool | |
3096 | Waarschuwing | Cellular signal strength low | The RSSI value for the cellular connection is under the defined threshold value of -98 dBm. | Move the tool closer to the cellular antennas for a stronger connection and avoid data loss. | Conf | IxB | Controller, Drive and Synchronized tightening |
3097 | Waarschuwing | XML-verbinding verloren | The system lost connection to the cellular network. |
| Log Display Conf | IxB | Controller, Drive and Synchronized tightening |
3100 | Waarschuwing | Modusconfiguratie bestaat niet | Select an existing sync mode before starting a tightening. | Log Display | Flex Synchronized tightening | Controller, Drive and Synchronized tightening | |
3150 | Fout | Software IAM Incompatibility | IAM is incompatible with the software that is installed on the controller. | Replace IAM. | Log Display Ack | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 | Controller, Drive and Synchronized tightening |
3160 | Fout | Activeren van nieuw geïnstalleerde software mislukt | Something went wrong during the activation. When the newly installed software starts, a fallback to the previous working software happens. This error happens when the new software fails to start for three times and only during software installation. | Take an export and contact Atlas Copco for further assistance. Note down the software version you are trying to install as well as the software version that is working. | Log Display Ack | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 | Controller, Drive and Synchronized tightening |
3161 | Fout | Started On Unexpected Software Partition | The controller has started on the inactive software side and not on the expected software side. | Note down the software information (on the Home screen of the controller, select Controller > Software). Try to restart the controller and make sure its running on correct software when started again. If error persists, do an export and contact Atlas Copco. | Log Display Ack | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 | Controller, Drive and Synchronized tightening |
3162 | Info | Software Upgrade Verification Failed | Failed to verify the integrity and authenticity of the software package. | Ensure that the software package that is being upgraded to is a signed, software package. Note down the software information (on the Home screen of the controller, select Controller > Software). If error persists, do an export and contact Atlas Copco. | Log Display Ack | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 | Controller, Drive and Synchronized tightening |
3180 | Info | Software Adapter Import Verification Failed | Failed to verify the integrity and authenticity of the imported protocol adapters. | Make sure that the protocol adapters that are being imported are signed, protocol adapters. If error persists, do an export and contact Atlas Copco. | Log Display Ack | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 | Controller, Drive and Synchronized tightening |
3200 | Waarschuwing | Fout in modusconfiguratie | Invalid or missing SPC configuration detected. | Invalid or incomplete SPC configuration detected. Review SPC parameters and limits. Correct SPC configuration. | Log Conf Display | IxB Power Focus 6000 Power Focus 8 | Controller |
3500 | Fout | Algemene licentiebeheerfout | Inconsistency detected in the feature management system used. | Neem contact op met uw Atlas Copco vertegenwoordiger. | Log Display Ack | IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Controller, Drive and Synchronized tightening |
3501 | Fout | Fout in synchronisatie licentiebeheer | Synchronization with the license server failed. | Contact Atlas Copco service representative. | Log Display Ack | IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Controller, Drive and Synchronized tightening |
3502 | Info | Synchronisatie licentiebeheer voltooid | Synchronization with the license server completed. | IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Controller, Drive and Synchronized tightening | ||
3503 | Waarschuwing | License Manager: Another Source in Use | License is used by another source. | Verify license assignment. | Log Display | IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Controller, Drive and Synchronized tightening |
3504 | Waarschuwing | License Manager Restart Needed | Restart license manager. | Log Display | IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Controller, Drive and Synchronized tightening | |
3505 | Info | USB Licentiesynchronisatie gestart | Moving licenses from the USB license dongle started. | Log | Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl Power Focus 500 | Controller, Drive and Synchronized tightening | |
3506 | Fout | USB Licentiesynchronisatie fout | Moving licenses from the USB license dongle failed. | Contact Atlas Copco service representative. | Log | Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl Power Focus 500 | Controller, Drive and Synchronized tightening |
3507 | Info | USB Licentiesynchronisatie gereed | Moving licenses from the USB license dongle done. | Log | Power Focus 6000 Power Focus 8 Power Focus 500 | Controller, Drive and Synchronized tightening | |
3508 | Info | One or more of your licenses are about to expire. Please make sure you have a license server configured | Update licenses. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Controller, Drive and Synchronized tightening | |
3509 | Fout | Too many FMS Portables in use. Please return licenses to a previously used FMS Portable in order to use this one. | Too many license dongles are connected. | More license dongles connected than supported. Verify number of connected dongles. Remove excess dongles. | Log Display Ack | Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 | Controller |
3510 | Fout | There is already a Local License Server in use. Return all licenses to the server prior to configuring a new one. | Inconsistency detected in a license to be used during configuration. | Update licenses. | Log Display Ack | ToolsControl | Controller |
3511 | Waarschuwing | One of your licenses has a different license definition | Inconsistency detected in a license to be used. | Neem contact op met uw Atlas Copco vertegenwoordiger. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl Power Focus 500 | Controller, Drive and Synchronized tightening |
3512 | Fout | Unexpected license service error. Neem contact op met Atlas Copco voor hulp. | Neem contact op met uw Atlas Copco vertegenwoordiger. | Log Conf Display Ack | ToolsControl | Controller | |
3550 | Waarschuwing | Licentie ontbreekt | Install the correct license. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl Power Focus 500 | Controller, Drive and Synchronized tightening | |
3551 | Waarschuwing | Wireless Communication Disabled By Licensing | Unassign Standalone license from the Virtual Station. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Controller, Drive and Synchronized tightening | |
3600 | Info | System restart triggered by user | Restart is triggered as a consequence of a user action within the system, such as:
| Log Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 Power Focus 500 | Controller and Tool | |
3601 | Info | Unexpected system shut down | The system rebooted or shut down unexpectedly | Log Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 Power Focus 500 ToolsControl | Controller and Tool | |
3610 | Info | System shut down due to power loss | Power switch is pressed or controller is disconnected from power source | Log Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 Power Focus 500 ToolsControl | Controller and Tool | |
3611 | Info | Backup battery timer timed out, shutting down | Tool have been runnning on backup battery for more than 20s | Log Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 Power Focus 500 ToolsControl | Controller and Tool | |
3612 | Info | System shut down due to inactivity | Inactivity timeout has expired | Log Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 Power Focus 500 ToolsControl | Controller and Tool | |
3700 | Info | A broken result has been discarded. | Partial or incomplete result which is classified as broken has been discarded. | Log Conf Ack | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 | Controller | |
4010 | Info | Gereedschap vergrendeld door digitale ingang | The tool is locked by a digital input signal. | Log Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Tightening Process | |
4011 | Info | Gereedschap vergrendelen door Open Protocol | Het gereedschap is vergrendeld. | Log Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Tightening Process | |
4012 | Info | Gereedschap vergrendeld door Fieldbus | The tool is locked by the Fieldbus. | Log Display Conf | Flex Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 | Tightening Process | |
4013 | Info | Gereedschap vergrendeld door dopselector | Tool is locked when the socket selector is disconnected from the Virtual Station. | Unlock by Master Unlock. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process |
4014 | Info | Gereedschap vergrendeld door Graph PLC | Soft PLC signal locked the tool. | Unlock by Master Unlock. | Log Display Conf | Flex Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 | Tightening Process |
4015 | Info | Losdraaien uitgeschakeld | Loosening is disabled in the tightening program. | Log Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl XB | Tightening Process | |
4016 | Info | Aandraaien uitgeschakeld | Log Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl XB | Tightening Process | ||
4017 | Info | Losdraaien niet geconfigureerd | Loosening is not configured in the selected tightening program | Select different tightening program. | Log Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Tightening Process |
4020 | Info | Te veel NOK aandraaiingen | Maximum consecutive NOK tightenings in batch is exceeded | Log Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Tightening Process | |
4021 | Info | Too many consecutive loosenings | Maximum consecutive loosenings configured in General Virtual Station has been reached | An external input has to unlock and reset by signal Reset too many loosening lock or Master unlock. | Log Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Sync Power Focus 500 ToolsControl | Groepen |
4025 | Info | Geen aandraaiprogramma geselecteerd | Geen aandraaiprogramma geselecteerd | Select tightening program or batch sequence. | Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process |
4030 | Info | Batchreeks afgebroken | The batch sequence has been aborted. | Log Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 Power Focus 500 ToolsControl | Tightening Process | |
4031 | Info | Max. tijd voor voltooiing batchreeks overschreden | Log Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Tightening Process | ||
4032 | Info | Max. tijd tot eerste aandraaiing overschreden | Log Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Tightening Process | ||
4033 | Waarschuwing | Max. tijd tot eerste aandraaiing overschreden | Tightening exceeded the maximum allowed time. | Tightening exceeded allowed completion time. Check fastener presence and tightening program. Correct fastening condition or parameters. | Log Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 | Controller and Tool |
4034 | Waarschuwing | Max time to complete operations in work zone exceeded | Operation exceeded the allowed time in the work zone. | Operation exceeded allowed work zone time. Verify work zone configuration and sequence. Adjust work zone or operation flow. | Log Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening | Controller and Tool |
4035 | Info | Vergrendeld door lijnregeling | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | ||
4040 | Info | Vergrendeld door alternatieve identificator | Vergrendeld door alternatieve identificator | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4050 | Ongeldige dopconfiguratie | Tightening program assigned to multiple sockets. | Tightening program assigned to multiple sockets. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4060 | Info | Tool Locked On Batch Complete | When running a batch with flag Tool lock on batch sequence complete this event is generated when the user press the trigger. | Unlock with signal Unlock Tool on complete. | Log Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Tightening Process |
4061 | Info | Tool locked by tool diagnostic mode | Tool is locked due to diagnostics mode is ON. | Tool locked due to active diagnostics mode. Check tool mode in controller. Exit diagnostics mode to unlock tool. | Log Display Conf | Power Focus 6000 Power Focus 8 Power Focus 500 | Controller and Tool |
4062 | Info | Tool Locked By Result Synchronization | Results from tool are being synchronized with the controller. | Wait until result sync is done to restart work. | Log Display Conf Ack | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Tightening Process |
4063 | Info | Tool Locked due to transducer redundancy error | Tool is locked due toredundancy error. | Log Display | Power Focus 6000 ToolsControl | ||
4064 | Info | Tool Locked by Automation Rules | Tool is locked by Automation rules. | No action | Log Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | |
4065 | Info | Tool locked by test tightening | Tool is started when test tightening mode is active. | Exit test tightening | Log Conf Display | Flex Synchronized tightening | Tightening Process |
4070 | Info | Process Enter Manual Mode | Indicates that manual mode has been activated for a virtual station. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4071 | Info | Process Enter Automatic Mode | Indicates that automatic mode has been entered for a virtual station. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4072 | Info | Test Bolt | Conf | Flex Synchronized tightening | Tightening Process | ||
4073 | Info | Tool zero position updated | Indicates that the tool zero position is set using signals. | Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Tightening Process | |
4100 | Waarschuwing | Identifier Not Accepted: Invalid String Length | Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Tightening Process | ||
4101 | Waarschuwing | String Selection Unsuccessful: Multiple Matches | Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Tightening Process | ||
4102 | Waarschuwing | String Selection Unsuccessful: No Match Found | Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Tightening Process | ||
4103 | Waarschuwing | Identifier Not Accepted: Identical String Already Received | Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Tightening Process | ||
4104 | Waarschuwing | Identifier Not Accepted: No Match Found | Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Tightening Process | ||
4105 | Waarschuwing | Assembly task selection unsuccessful: No match found | Log Conf Display | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening ToolsControl | Controller | ||
4106 | Waarschuwing | Assembly task selection unsuccessful: Multiple matches | Log Conf Display | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening ToolsControl | Controller | ||
4107 | Waarschuwing | Wrong location for selected assembly task | The assembly work task has been configured to use device location to validate but not select assembly tasks. The selected assembly task is allowed to start when the controller/tool is at the expected location. | Move the controller to the expected work zone. | Log Conf Display | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening ToolsControl | Controller |
4108 | Waarschuwing | The assembly work task has been deleted | The active assembly work task (selected in the virtual station) has been deleted. | Select the new/correct assembly work task as the task in the virtual station. | Log Conf Display | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening ToolsControl | Controller |
4109 | Waarschuwing | The assembly task has already been completed | Log Conf Display | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening ToolsControl | Controller | ||
4110 | Waarschuwing | The selected assembly task is uncompleted | New input has been provided to the controller suggesting that a new assembly task should be selected when one is already selected and in progress (i.e. at least one tightening has been performed). | Return to the work zone and complete the started assembly task or abort it to be able to select another assembly task. | Log Conf Display | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening ToolsControl | Controller |
4111 | Waarschuwing | Invalid assembly task priorities | In the controller there are at least two different assembly tasks which are configured with the same priority value. This is not allowed if the assembly tasks are supposed to be selected together one after the other i.e. a multiselection. | Check the assembly task configurations. | Log Conf Display | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening ToolsControl | Controller |
4112 | Waarschuwing | PAT build data has been requested | The assembly work task has been configured to request new PAT build data when an unknown product identifier is provided to the controller. Such a request has been made and while in progress the tool will be locked until it either succeeds or time out. | Wait for request to complete or time out. | Log Conf Display | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening ToolsControl | Controller |
4113 | Waarschuwing | PAT build data is missing | The assembly work task has been configured to request new PAT build data when an unknown product identifier is provided to the controller. Such a request has been made and was unsuccessful i.e. the provided product identifier is still unknown. | Check PAT build data and data/logs in customer upper layer system | Log Conf Display | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening ToolsControl | Controller |
4114 | Waarschuwing | External dependencies not ready | The assembly task has been configured to require clearance from a customer upper layer system before it is allowed to be selected. | Check PAT build data and data/logs in customer upper layer system | Log Conf Display | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening ToolsControl | Controller |
4115 | Waarschuwing | No assembly task selected | Log Conf Display | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening ToolsControl | Controller | ||
4116 | Waarschuwing | Assembly task aborted, process timer expired | The assembly task has been configured to use one or more process timers which will trigger an abort if not satisfied in time. See the assembly task configuration for more details. | Log Conf Display | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening ToolsControl | Controller | |
4117 | Waarschuwing | Assembly task resume error, abort required | The assembly task to resume (or the parent assembly work task) has been modified in such as way that it cannot be resumed. An abort is required to confirm this, which will then allow new assembly task selections to be made. | Preform an abort. On IXB tools this can be done in the batch operations menu the EHMI/RHMI. | Log Conf Display | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening ToolsControl | Controller |
4119 | Waarschuwing | Assembly task not found | The list of assembly task IDs in the assembly work task contains at least one invalid ID (the corresponding assembly task does not exist in the controller). | Check the assembly work task configuration | Log Conf Display | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening ToolsControl | Controller |
4120 | Waarschuwing | Assembly task configuration error | General error code for an unknown assembly task configuration error. | Check the assembly task configurations. See the worktask log for details. | Log Conf Display | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening ToolsControl | Controller |
4121 | Waarschuwing | Tightening task not set for assembly task | An assembly task doesn't have a tightening task (tightening program or batch sequence etc.) configured. | Check the assembly task configurations. | Log Conf Display | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening ToolsControl | Controller |
4122 | Waarschuwing | Tightening task not found for assembly task | The id of the configured tightening task in an assembly task is invalid (the corresponding tightening task doesn't exist in the controller). | Check the assembly task configurations. | Log Conf Display | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening ToolsControl | Controller |
4123 | Waarschuwing | Assembly task has no joint ids | An assembly task is configured to use "Batch control - Joint id" but no joint ids have been configured and none can be found in the PAT build data. | Check the assembly task configurations and PAT build data. | Log Conf Display | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening ToolsControl | Controller |
4500 | Info | Result DriveError | Internal driver error or driver loss detected. | Conf | Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4501 | Info | Result Rehit | Attempt to tighten an already tightened bolt when Rehit detection is on. | Step Category for the Start Stage must be set to Soft Start. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process |
4502 | Info | Zachte start koppel laag | Soft start torque below minimum level. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4503 | Info | Zachte start koppel hoog | Soft start torque exceeded maximum level. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4504 | Info | Zelftap koppel hoog | Self-tap torque exceeded maximum level. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4505 | Info | Zelftap koppel laag | Self-tap torque below minimum limit. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4506 | Info | Result Safety Torque Low | Automatically calculated torque value to ensure torque sensor is mounted correctly. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4507 | Info | Result Rundown Torque High | Rundown torque exceeded maximum level. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4508 | Info | Result Rundown Angle High | Rundown angle exceeded maximum level. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4509 | Info | Result Rundown Time High | Rundown time exceeded maximum limit. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4510 | Info | Result Rundown Time Low | Rundown time below minimum limit. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4511 | Info | Result Rundown Torque Low | Rundown torque below minimum level. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4512 | Info | Result Rundown Angle Low | Rundown angle below minimum level. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4513 | Info | Result Final Torque High | Final step torque exceeded maximum level. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4514 | Info | Result Final Angle High | Final step angle exceeded maximum level. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4515 | Info | Result Final Torque Low | Final step torque below minimum level. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4516 | Info | Result Final Angle Low | Final step angle below minimum level. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4517 | Info | Result Tightening Timeout | Tightening time limit exceeded. For General Tightening Strategies max tightening time is 30 seconds. For Multistep max tightening time depends on step restriction Maximum Time Limit. Error code is dependent on tightening stage. | Redo tightening. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process |
4518 | Info | Result Trigger Lost | Tool trigger was released before target was reached. For General Tightening Strategies it is not allowed to release the trigger before the tightening stage has finished. For Multistep, the error is displayed when trigger is lost before the target in a specific step is reached. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4519 | Info | Premature Torque Loss | Socket has slipped off the nut. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4520 | Info | Doel bereikt voor laatste stap | Target torque reached before final step in tightening program. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4521 | Info | Postweergave koppel laag | Post view torque below minimum level. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4522 | Info | Postweergave koppel hoog | Post view torque exceeded maximum level. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4523 | Info | Postweergave koppelinterval niet bereikt | Postweergave koppelinterval niet bereikt | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4524 | Info | Koppelcompensatie-interval niet bereikt | Torque compensation interval angle before rundown end not reached. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4525 | Info | Result Tool Movement Exceeded | From a NOK tightening detailed status. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4526 | Info | Result SafetyCurrMon Sensor Mismatch | Stroombewakingsfout | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | ||
4527 | Info | Result Tool Movement Exceeded | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |||
4538 | Info | Eindcontrole koppel laag | Final Supervision Torque was not reached. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4543 | Info | Result Snug Monitor High | Wrench only. Monitor detected snug value exceeded. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4545 | Info | Result No Residual Torque | Wrench only. Residual torque was under threshold. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4546 | Info | Result Overspeed | Wrench only. Wrench gyro failed to measure angle due to high speed. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4547 | Info | Resultaat effectief losdraaien | Wrench only. Sleutel heeft onverwacht doorbuigen gedetecteerd | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4548 | Info | Result Final Less Than Target | Final torque is below target torque set in tightening program. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4549 | Info | TurboTight Time Limit Exceeded | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | ||
4550 | Info | Result Rundown Pulses High | Maximum number of rundown pulses is exceeded. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4551 | Info | Result Rundown Pulses Low | Rundown is completed before the minimum number of rundown pulses is reached. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4552 | Info | Result Final Pulses High | Maximum number of pulses is exceeded. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4553 | Info | Result Final Pulses Low | Tightening is completed before the minimum number of pulses is reached. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4554 | Info | Current At Shutoff High | Current at shut off exceeded Current Limit High. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4555 | Info | Current At Shutoff Low | Shut off current measured was below Current Limit Low. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4556 | Info | Ongecategoriseerde meerstapsfout | An error in the multistep configuration, often with tool validation. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4557 | Info | Result Overload | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | ||
4558 | Info | Result pulse drive socket not detected | Pulse drive socket was not detected. | Pulse drive socket not detected by tool. Check socket installation and compatibility. Install correct socket or service tool. | Log Display | Power Focus 6000 Power Focus 8 | Controller |
4559 | Info | Result Stopped | The event is triggered when an external stop signal or lock signal is aborting an ongoing tightening. The event is introduced to distinguish between trigger loss and external stop. | Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Tightening Process | |
4600 | Waarschuwing | Data Drop or Data Hold used in combination with Batch Tightening. The signals have no effect | Data Drop and Data Hold are only supported for worktasks, without batch control. Select another worktask if the signals must be used. | Flex Synchronized tightening | Tightening Process | ||
4601 | Info | Data Hold Active: tightening result is sent once signal is low | Flex Synchronized tightening | Tightening Process | |||
4602 | Info | Data Drop active: tightening result discarded | Flex Synchronized tightening | Tightening Process | |||
5010 | Waarschuwing | Invalid Tightening Program Parameter Value | The parameter in the selected tightening program are invalid. | Check the configuration of the selected tightening program to find and to change the value of the parameter. | Log Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 Power Focus 500 ToolsControl | Program Configuration |
5011 | Waarschuwing | Couldn't prepare program storage in tool | It is not possible to read the current program storage size in the tool, or to prepare the program storage for downloading the updated, or newly selected program to the tool. |
| Log Display Conf | Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Program Configuration |
5020 | Info | Hoofdtrekker is geen actieve startbron | Generated when configured for push start only and user presses main trigger. Will be generated until user presses the push start. | Druk op de drukknop om het gereedschap te starten. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Program Configuration |
5030 | Info | Complexiteit aandraaiprogramma overschrijdt gereedschapscapaciteit | The selected tightening program is too complex for the STB tool that is used. Tool will be locked. | Reduce complexity of the tightening program, or choose different program. | Log Display Conf | Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Program Configuration |
6010 | Info | Accessoire aangesloten | Accessory is connected to the controller. | Log Display Ack Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Accessoire | |
6020 | Info | Accessoire losgekoppeld | Accessory is disconnected from the controller. | Log Display Ack Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Accessoire | |
6021 | Waarschuwing | Fieldbus offline | No communication with Fieldbus. | Log Display Ack Conf | Flex Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 | Accessoire | |
6022 | Info | FIELDBUS_ONLINE | Field bus communication Established | Log Display Ack Conf | Flex Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 | Accessoire | |
6030 | Waarschuwing | Adresconflict accessoire | Two or more accessories with the same address are connected. | Change address on accessory. | Log Display Ack Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Accessoire |
6040 | Waarschuwing | Communicatiefout accessoire | Intermittent communication error with accessory. | Check cables and connectors. | Log Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Accessoire |
6041 | Waarschuwing | Fieldbus Error | Fout in communicatie met gereedschap |
| Log Display Ack Conf | Flex Power Focus 6000 Power Focus 8 Synchronized tightening | Accessoire |
6042 | Waarschuwing | Fieldbus hardwaremismatch | The installed Fieldbus module does not match with the configured module. | Change the configuration to match with the installed module, or replace the installed module with the correct one. | Log Display Ack Conf | Flex Power Focus 6000 Power Focus 8 Synchronized tightening | Accessoire |
6043 | Waarschuwing | Fieldbus Output Buffer Overflow | The output buffer used for the Fieldbus communication is exhausted and an overflow of the buffer has occurred. One or more signal updates have been discarded. | Stop Fieldbus communication and Fieldbus diagnostics (if used) to recover the buffer. If this event occurs frequently, check your Fieldbus communication setup, including the PLC program: too frequent updates compared to your update interval can lead to this scenario. | Log Display Ack Conf | Flex Power Focus 6000 Power Focus 8 Synchronized tightening | Accessoire |
6044 | Waarschuwing | Fieldbus Provider ID mismatch | The installed Fieldbus module is not supported. | Connect a supported Atlas Copco fieldbus module. | Log Display Ack | Power Focus 8 | Accessoire |
6045 | Waarschuwing | Fieldbus frame size too large for current system | The configured frame size in the fieldbus configuration is too large and not supported by the current system type. This may happen when importing configurations from different system types. | Check your general fieldbus configurations and adjust the frame size to and from the system. Perform the necessary adjustments to your mapped virtual stations and their fieldbus configurations to fit the smaller fieldbus frame supported by the current system. | Log Display Ack Conf | Flex | Accessoire |
6050 | Info | Onjuiste dop geselecteerd | Generated when no or incorrect socket is selected. | Log Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Accessoire | |
6090 | Waarschuwing | Barcode Scanner Could Not Be Identified | When no unique serial number is found. | Configure the barcode reader device. | Log Display Ack Conf | Flex Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 Power Focus 500 | Accessoire |
6500 | Waarschuwing | Invalid Rule Configuration | Rule configuration is invalid if the virtual station mapped does not exist, invalid cease configuration or if the rule has no triggers or no actions | Verify the configuration of the tool. | Log Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | |
6501 | Waarschuwing | Rule Triggered While Running | Running rule is re-triggered by the same trigger. | Disable and enable the rule. | Log Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | |
6502 | Info | Failed to execute Action | Rule fails to execute an event when it cannot perform an action on a deleted or non-existent virtual station. This occurs when the virtual station configured for the rule has been removed. | Action is corrected rule is disabled and enabled. | Log Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | |
6503 | Waarschuwing | Running Rule Deleted | This event occurs if a currently running rule is deleted. The action will not be reset if running rule is deleted. | No action. | Log Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | |
6504 | Waarschuwing | Running Rule Disabled | This event occurs if a currently running rule is disabled. The action will not be reset if running rule is disabled. | No action. | Log Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | |
6505 | Waarschuwing | Running Rule Updated | Running rule updated event if a currently running rule is updated. | No action. | Log Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | |
7010 | Info | Weer te geven berichttekst | General event for displaying of messages. | Display Ack Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 Power Focus 500 ToolsControl | Bericht | |
8135 | Info | Machine capability test mode activated | Machine capability test mode has been activated. The mode allows targeted steps within a multistage configuration to not be executed while the mode is active. | Activate Machine capability test mode. | Log Conf Display Ack | Power Focus 6000 Power Focus 8 Flex Power Focus 500 IxB XB | Controller |
8136 | Info | Machine capability test mode deactivated | Machine capability test mode has been deactivated. All steps within a multistage program will be executed as normal. | Deactivate Machine capability test mode. | Log Conf Display Ack | Power Focus 6000 Power Focus 8 Flex Power Focus 500 IxB XB | Controller |
8200 | Info | Openen van seriële poort mislukt | Serial port to be used could not be opened. | Check serial port connections. | Display Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 | Overig |
8300 | Waarschuwing | Open Protocol client communication timed out | Communication to an Open Protocol client has timed out. No keep alive message or command sent within expected time. |
| Log Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 ToolsControl | Overig |
8214 | Fout | EHMI-softwareversie komt niet overeen | EHMI software version does not match in compatibility with the controller. | Update the software version of the EHMI. | Log Display Ack Conf | IxB Power Focus 6000 Power Focus 8 Power Focus 500 ToolsControl | Overig |
8400 | Info | Controller event | Deleted configuration history. | Log Display Conf | Flex IxB Power Focus 6000 Power Focus 8 Synchronized tightening Power Focus 500 Power Focus 500 ToolsControl STRw Sync | Controller |