Installing the Controller

The controller must be positioned so that the power switch is easily accessible.

For maximum tool performance, make sure that the controller is installed so that free airflow is provided. This improves the cooling of the controller.
Attach the mounting plate to a wall or to a steel plate, using three M6 screws. If attaching to a wall, use the correct wall bracket (plug and screw). If attaching to a steel plate, make sure that the steel plate is at least 2 mm thick.
Attach the controller to the mounting plate by tilting the controller and guiding the top flange of the mounting plate into the slot on the back of the controller. Lower the controller to engage the locking mechanism.
Install the retainer strap between the wall and the cable cover.
Open the front access door of the controller.
Connect the power cable to the power connector.
Place the IAM in its socket on the back of the front access door.
Make sure that the RCBO (residual-current device) is switched on.
Close the front access door.
Connect the tool cable to its socket on the bottom part of the controller.
Connect the power cable to a power supply.
Turn the power switch on.

An optional, threaded grounding point is available on the lower backside of the controller. The grounding point accepts a M4 threaded screw. The additional grounding does not replace the grounding from the wall socket.