Relays
Relays Relay out
There are 8 relayoutputs. Normally open or normally closed depending on the connection.
Connector
24-pin detachable screw terminal. Mating connector Phoenix MCVR 1.5/12-ST.3.81 or compatible.
Function
Two way dry contact relays. Isolated outputs. Logical function is set in the configuration of the PowerFocus or DS-drive.
Electrical data
Max 50VDC/AC. Switching load: min 1mA, max 500 mA resistive load.
Pos. No.  | Function  | 
|---|---|
1  | Relay 5 normally open  | 
2  | Relay 5 common  | 
3  | Relay 5 normally closed  | 
4  | Relay 6 normally open  | 
5  | Relay 6 common  | 
6  | Relay 6 normally closed  | 
7  | Relay 7 normally open  | 
8  | Relay 7 common  | 
9  | Relay 7 normally closed  | 
10  | Relay 8 normally open  | 
11  | Relay 8 common  | 
12  | Relay 8 normally closed  | 
13  | 24V external output  | 
14  | 24V external output  | 
  | |
25  | Relay 5 normally open  | 
26  | Relay 5 common  | 
27  | Relay 5 normally closed  | 
28  | Relay 5 normally open  | 
29  | Relay 5 common  | 
30  | Relay 5 normally closed  | 
31  | Relay 5 normally open  | 
32  | Relay 5 common  | 
33  | Relay 5 normally closed  | 
34  | Relay 5 normally open  | 
35  | Relay 5 common  | 
36  | Relay 5 normally closed  | 
37  | 24V external ground  | 
38  | 24V external ground  | 
Screw terminal

External output