Current Monitoring
Current monitoring provides an extra security to monitor the tightening torque and is a complement to the torque sensor in the tool.
At final target torque, the rotor current is measured and converted to a torque value. If the calculated torque is within 10% of the measured torque, the tightening is considered to be OK.
Parameter  | Description  | Default  | 
|---|---|---|
Current monitoring  | Switch with On - Off position. 
  | Off  | 
Current monitoring is not implemented for Turbo Tight, Rotate, Pulsing and STwrench strategies.