Calibrating the position of the indexing stop nut
Required tools
-
Vise
-
Open-end spanner
-
Place the indexing stop nut roughly in position, and perform drill test holes to decide a more exact position.
Always tighten the upper nut using an open-end spanner, before a test hole is drilled.
-
Make the final adjustments to the position by turning the lower part of the nut using an open-end spanner.
When making the final adjustments, the upper nut should be tightened lightly by hand. For each adjustment of 0.02 mm, a "click" is felt when turning the lower nut.
-
When the position is correct, tighten the upper locking nut using an open-end spanner.