ILT Base Station
Product Information
General Information
Safety Signal Words
The safety signal words Danger, Warning, Caution, and Notice have the following meanings:
DANGER | DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. |
WARNING | WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury. |
CAUTION | CAUTION, used with the safety alert symbol, indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. |
NOTICE | NOTICE is used to address practices not related to personal injury. |
Warranty
Product warranty will expire 12+1 months after dispatch from Atlas Copco's Distribution Center.
Normal wear and tear on parts is not included within the warranty.
Normal wear and tear is that which requires a part change or other adjustment/overhaul during standard tools maintenance typical for that period (expressed in time, operation hours or otherwise).
The product warranty relies on the correct use, maintenance, and repair of the tool and its component parts.
Damage to parts that occurs as a result of inadequate maintenance or performed by parties other than Atlas Copco or their Certified Service Partners during the warranty period is not covered by the warranty.
To avoid damage or destruction of tool parts, service the tool according to the recommended maintenance schedules and follow the correct instructions.
Warranty repairs are only performed in Atlas Copco workshops or by Certified Service Partners.
Atlas Copco offers extended warranty and state of the art preventive maintenance through its ToolCover contracts. For further information contact your local Service representative.
For electrical motors:
Warranty will only apply when the electric motor has not been opened.
Website
Information concerning our Products, Accessories, Spare Parts and Published Matters can be found on the Atlas Copco website.
Please visit: www.atlascopco.com.
ServAid
ServAid is a portal that is continuously updated and contains Technical Information, such as:
Regulatory and Safety Information
Technical Data
Installation, Operation and Service Instructions
Spare Parts Lists
Accessories
Dimensional Drawings
Please visit: https://servaid.atlascopco.com.
For further Technical Information, please contact your local Atlas Copco representative.
Safety Data Sheets MSDS/SDS
The Safety Data Sheets describe the chemical products sold by Atlas Copco.
Please consult the Atlas Copco website for more information www.atlascopco.com/sds.
Country of Origin
For the Country of Origin, please refer to the information on the product label.
Dimensional Drawings
Dimensional Drawings can be found either in the Dimensional Drawings Archive, or on ServAid.
Please visit: http://webbox.atlascopco.com/webbox/dimdrw or https://servaid.atlascopco.com.
Overview
General Description
With the ILT, the wireless tool location solution by Atlas Copco, your battery tools will only operate in the correct area. Using wireless distance measurement technology, it tethers the tool to a specific workstation and disables the tool if it goes outside the set working range. This feature provides a virtual cable. Tool orientation detection continuously monitors the tool’s orientation. Users can define criteria for both roll and pitch angles, giving joint differentiation in certain applications.
Features
UWB radio technology with high precision
Tool-orientation detection
Integrated touch display
Communication via Open Protocol
Connect to Power Focus 4000
Connect to Power Focus 6000
Does not require ‘line of sight’
Tool tag accessories
Benefits
Enables flexible production
Simple and standalone installation
Easy to set up system and configure
Less down-time in production
Orientation functionality
System Overview
ILT Base Station
A | Touch screen | B | Status LED |
A | Attachment tabs | B | Mounting hole |
ILT Tool Tag
The ILT Tool Tag must be purchased separately.
A | Power LED | B | Status LED |
C | Label |
The Status LED on the ILT Tool Tag shows the current connection status and if the tool is enabled or disabled.
Alternating between red and blue: The ILT Base Station is searching for the ILT Tool Tag.
Red light: The ILT Tool Tag is not connected to the ILT Base Station.
Blue light: The tool is disabled.
Green light: The tool is enabled.
The Power LED on the ILT Tool Tag shows the power status.
Green light: The ILT Tool Tag has power.
No light: The ILT Tool Tag has no power.
Cables
One 5 meter ILT Power Cable, is included when purchasing the ILT Base Station.
The Ethernet cable, for connecting to the controller, must be purchased separately.
Technical Product Data
Technical Product Data can be found on either ServAid, or the Atlas Copco website.
Please visit: https://servaid.atlascopco.com or www.atlascopco.com.
Accessories
Additional Products
In addition to the ILT Base Station the following accessories need to be purchased separately:
ILT Tool Tags, there are different tags available depending on which tool they will be mounted on.
Ethernet cable, see the ILT Base Station User Guide for more information regarding Ethernet cables.
Optional, serial cable (for Power Focus 4000 only).
Optional, Adapter Cable (for Power Focus 6000 only).
Additional information about the available accessories is available at: https://servaid.atlascopco.com.
Power Supply
A | Ethernet, D-coded M12 female | B | Power I/O, 10-30 VDC ∼5 W, M8 male A-coded |
C | USB type A, for USB drive | D | COM, RS-232, M8 female A-coded |
Power is supplied to the ILT Base Station by 24 VDC through the connector marked “PWR”. It is recommended to connect the included power cable directly to the 24V and GND outputs on the Power Focus controller.
Make sure the Power Focus is turned off when connecting the ILT Base Station.
Power (PWR) and Input/Output IO connector
Pin | Wire color in the connected cable | Signal |
---|---|---|
1 | Brown | +10-30 VCD in, ∼5 W |
2 | White | Relay 1 Common Solid state relay, Galvanically isolated, 30V AC/DC, 1A, Internal resistance 0.15Ω |
4 | Black | Relay 1 Normally open Solid state relay, Galvanically isolated, 30V AC/DC, 1A, Internal resistance 0.15Ω |
3 | Blue | GND (System ground) |
RS-232 serial connector (COM)
Pin | Wire color in the connected cable | Signal |
---|---|---|
1 | Brown | GND (System ground) |
2 | White | RS-232 Tx |
4 | Black | RS-232 Rx |
3 | Blue | GND (System ground) |
Installation
Installation Instructions
General Mounting Directions
For optimal performance, mount the ILT Base Station with the list below in mind
Do not place the ILT Base Station behind a metal object.
Place the ILT Base Station close to the center of the tethering zone.
Place the ILT Base Station so that it can be viewed and operated.
Mount the ILT Base Station maximum 2 meters above the floor.
If mounted higher than 2 meters above the floor, use additional safety equipment (for example, a steel wire) to secure the ILT Base Station to a rigid object.
Mounting the ILT Base Station using Attachment Tabs
To attach the top and the bottom of the ILT Base Station use the four attachment tabs included in the box. Mount the ILT Base Station to a suitable surface.
Separate instructions on how to mount the tabs to the ILT Base Station are included in the box.
Mounting the ILT Base Station using the Threaded Mounting Hole
Use the threaded M8 hole in the back of the ILT Base Station, to mount it to a structure, bracket or attachment.
Do not use a bolt that can be threaded more than 20 mm into the M8 mounting hole as it can destroy the blind nut and damage the electronics inside.
Initial Configuration
Configuring the ILT Base Station
For information about configuration, refer to ILT Base Station User Guide.
Troubleshooting
Status LED
If the Status LED on the ILT Tool Tag is flashing, for example between green and blue, it is possible that the tag is connected to two ILT Base Station.
Disconnect the ILT Tool Tag from the ILT Base Station you are not using.
Recycling
Environmental Regulations
When a product has served its purpose it has to be recycled properly. Dismantle the product and recycle the components in accordance with local legislation.
Batteries shall be taken care of by your national battery recovery organization.
Recycling Information
Position | Part | Remark | Recycle as |
---|---|---|---|
1 | ILT Base Station | Electronics |