Lubrication
The tool is fitted with an angle gear which is lubricated with a fluid grease to ensure good wear resistance. To prevent overfilling, which could result in a rise in temperature and damage to seals, there is no lubrication nipple. Instead, the grease should be changed after approximately 1000 hours by removing the angle-gear spindle. Check every 500 running hours.
For accurate lubricating properties – use RHENUS LKR03 fluid type grease. For the requisite amount of grease, see table below.
Do not use ball bearing grease or chassis grease.
Amount of grease | Tool speed |
|---|---|
5 cm³ | 8000 / 12000 |
3 cm³ | 17000 / 20000 |