Lubrication

The tool is fitted with an angle gear which is lubricated with a fluid grease to ensure good wear resistance. To prevent overfilling, which could result in a rise in temperature and damage to seals, there is no lubrication nipple. Instead, the grease should be changed after approximately 1000 hours by removing the angle-gear spindle. Check every 500 running hours.

For accurate lubricating properties – use RHENUS LKR03 fluid type grease. For the requisite amount of grease, see table below.

Do not use ball bearing grease or chassis grease.

Amount of grease

Tool speed

5 cm³

8000 / 12000

3 cm³

17000 / 20000