Assembling the drive unit and assembling and lubricating the OG

  1. Insert the drive unit into the frame and connect the control cable to the circuit board.

  2. Hold the spindle by the drive unit using a vise and an adjustable spanner.

  3. Attach the locking pin and the ring, and tighten the ring nut using an adjustable spanner.

  4. Remove the spindle from the adjustable spanner.

  5.  

    1. Thread the motor cable through the hole in the frame.

    2. Connect the motor cable.

  6.  

    1. Thread the temperature sensor cable through the hole in the frame.

    2. Connect the temperature sensor cable.

  7. Attach the housing.

  8.  

    1. Thread the indicator cable through the hole in the frame

    2. Connect the indicator cable.

  9. Attach the two screws holding the housing, using an allen key

  10. Attach the cover.

  11. Mount the four screws holding the cover, using a screwdriver.

  12. Hold the OG using an adjustable spanner.

  13. Attach the OG to the spindle.

    The adjustable spanner holds the OG and the vise holds the spindle.

    Make sure the splines of the front part and the drive unit is aligned before attaching the front part. If the splines are not aligned mount a 1.5 hex bit to the front part and rotate the bit so the splines align.

  14. Lubricate the OG by adding grease.