Product Information

  • General Information
    • Symbols on the Tool
    • Safety Signal Words
    • Warranty
    • ServAid
    • Website
    • Safety Data Sheets MSDS/SDS
    • Country of Origin
    • Dimensional Drawings
  • Overview
    • Intended Use for Screwfeeding Tools
    • The Tensor System
    • Technical Product Data
  • Service Overview
    • Service Recommendations

General Information

WARNING

Risk of Property Damage or Severe Injury

Ensure that you read, understand and follow all instructions before operating the tool. Failure to follow all the instructions may result in electric shock, fire, property damage and/or severe bodily injury.

  • Read all Safety Information delivered together with the different parts of the system.

  • Read all Product Instructions for installation, operation and maintenance of the different parts of the system.

  • Read all locally legislated safety regulations regarding the system and parts thereof.

  • Save all Safety Information and instructions for future reference.

In this Section
  • Symbols on the Tool
  • Safety Signal Words
  • Warranty
  • ServAid
  • Website
  • Safety Data Sheets MSDS/SDS
  • Country of Origin
  • Dimensional Drawings

Symbols on the Tool

The symbols on the tool have the following meanings:

A

Directive 2006/42/EC on Machinery specifies the essential health and safety requirements the product has to meet in order for the manufacturer to affix the CE marking.

B

When operating the device be sure to use caution.

C

The symbol indicates that parts within the product must be handled in accordance with the WEEE Directive.

D

Read the instruction manual/booklet before starting work or before operating equipment or machinery.

Safety Signal Words

The safety signal words Danger, Warning, Caution, and Notice have the following meanings:

DANGER

DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.

WARNING

WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.

CAUTION

CAUTION, used with the safety alert symbol, indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

NOTICE

NOTICE is used to address practices not related to personal injury.

Warranty

  • Product warranty will expire 12 months after the product is first taken into use, but will in any case expire at the latest 13 months after delivery.

  • Normal wear and tear on parts is not included within the warranty.

    • Normal wear and tear is that which requires a part change or other adjustment/overhaul during standard tools maintenance typical for that period (expressed in time, operation hours or otherwise).

  • The product warranty relies on the correct use, maintenance, and repair of the tool and its component parts.

  • Damage to parts that occurs as a result of inadequate maintenance or performed by parties other than Atlas Copco or their Certified Service Partners during the warranty period is not covered by the warranty.

  • To avoid damage or destruction of tool parts, service the tool according to the recommended maintenance schedules and follow the correct instructions.

  • Warranty repairs are only performed in Atlas Copco workshops or by Certified Service Partners.

Atlas Copco offers extended warranty and state of the art preventive maintenance through its ToolCover contracts. For further information contact your local Service representative.

For electrical motors:

  • Warranty will only apply when the electric motor has not been opened.

ServAid

ServAid is a portal that is continuously updated and contains Technical Information, such as:

  • Regulatory and Safety Information

  • Technical Data

  • Installation, Operation and Service Instructions

  • Spare Parts Lists

  • Accessories

  • Dimensional Drawings

Please visit: https://servaid.atlascopco.com.

For further Technical Information, please contact your local Atlas Copco representative.

Website

Information concerning our Products, Accessories, Spare Parts and Published Matters can be found on the Atlas Copco website.

Please visit: www.atlascopco.com.

Safety Data Sheets MSDS/SDS

The Safety Data Sheets describe the chemical products sold by Atlas Copco.

Please consult the Atlas Copco website for more information www.atlascopco.com/sds.

Country of Origin

For the Country of Origin, please refer to the information on the product label.

Dimensional Drawings

Dimensional Drawings can be found either in the Dimensional Drawings Archive, or on ServAid.

Please visit: http://webbox.atlascopco.com/webbox/dimdrw or https://servaid.atlascopco.com.

Overview

  • Intended Use for Screwfeeding Tools
  • The Tensor System
  • Technical Product Data

Intended Use for Screwfeeding Tools

This product is a part of a bigger system and designed for installing and removing threaded fasteners in wood, metal or plastic. No other use permitted.

The Tensor System

The Tensor system consists of a range of tightening tools powered by brushless electric motors and different drive units.

Motors are available in different sizes. All tools are protected from overheating of the motor. Electrical protection system is based on an earth fault circuit brake, Earth Fault Protector (EFP). The EFP senses small current leakage (>30mA) and if leakage occurs, the drive is switched off (30ms). Changing, interfering or tampering with the protection system voids all warranty and obligations from Atlas Copco. Trouble-shooting and re-start of the system may only be carried out by an authorized person. Check the function of the EFP on a regular basis by pressing the trip-button. The EFP should switch off accordingly.

Technical Product Data

Technical Product Data can be found on either ServAid, or the Atlas Copco website.

Please visit: https://servaid.atlascopco.com or www.atlascopco.com.

Service Overview

  • Service Recommendations

Service Recommendations

Preventive maintenance is recommended at regular intervals. See the detailed information on preventive maintenance. If the product is not working properly, take it out of service and inspect it.

If no detailed information about preventive maintenance is included, follow these general guidelines:

  • Clean appropriate parts accurately

  • Replace any defective or worn parts

Installation

  • Installation Requirements
    • Socket release function
    • Tool display
    • Connecting the Tool
    • Grounding
  • Installation Instructions
    • Fitting of the Tool Cable

Installation Requirements

  • Socket release function
  • Tool display
  • Connecting the Tool
  • Grounding

Socket release function

It is recommended to use the socket release function on all the ETP ST101 tools. When the function is enabled, the socket rotates backwards 3° after a completed tightening. The aim is to reduce tension on the reaction bar and to make it easier to remove the tool.

The socket release function is turned on from the controller.

On Power Focus 4000:

  • Push the Prog button

  • Use the navigation buttons to follow the path > Pset > Programming+ > Options > Socket release > Mode On

Tool display

The tool display is turned on from the controller.

On Power Focus 4000:

  • Push the Prog button

  • Use the navigation buttons to follow the path > Tool > Configuration > Accessory bus > ST bus > Mode

Connecting the Tool

The tool should, via its correct Power Focus drive unit, be connected to the mains, 230V/50Hz alternatively 115V/ 60Hz, single phase. See instructions for your Power Focus drive unit.

Grounding

If the tool is mounted in a handheld or hand guided fixture, the fixture should be connected to the drive using a separate 2.5mm2 grounding cable.

Installation Instructions

  • Fitting of the Tool Cable

Fitting of the Tool Cable

  • Make sure that the tool cable is of correct type.

  • Align the cable connector using the two asymmetrically positioned heads on the connector to fit in the slots in the tool handle.

  • Tighten the lock nut.

  • Make sure that the connection is correct by pulling, pushing and turning the cable connector (there should be no movement).

The tool has a built in electronic memory chip that will transmit the torque transducer calibration value and angle pulses to the POWER FOCUS/drive unit. Any changes made of these values in the POWER FOCUS while the tool is connected will be stored in the tool memory.

Operation

  • Ergonomic Guidelines
  • Operating Instructions
    • Operating

Ergonomic Guidelines

Consider your workstation as you read through this list of general ergonomic guidelines to identify areas for improvement in posture, component placement, or work environment.

  • Take frequent breaks and change work positions frequently.

  • Adapt the workstation area to your needs and the work task.

    • Adjust for a convenient reach range by determining where parts and tools need to be located to avoid static load.

    • Use workstation equipment such as tables and chairs appropriate for the work task.

  • Avoid work positions above shoulder level or with static holding during assembly operations.

    • When working above shoulder level, reduce the load on the static muscles by lowering the weight of the tool, using for example torque arms, hose reels or weight balancers. You can also reduce the load on the static muscles by holding the tool close to the body.

    • Take frequent breaks.

    • Avoid extreme arm or wrist postures, particularly during operations requiring a degree of force.

  • Adjust for a convenient field of vision that requires minimal eye and head movements.

  • Use appropriate lighting for the work task.

  • Select the appropriate tool for the work task.

  • In noisy environments, use ear protection equipment.

  • Use high-quality inserted tools and consumables to minimize exposure to excessive levels of vibration.

  • Minimize exposure to reaction forces.

    • When cutting:

      A cut-off wheel can get stuck if the cut-off wheel is bent or not guided properly. Use the correct flange for the cut-off wheel and avoid bending the cut-off wheel during operation.

    • When drilling:

      The drill might stall when the drill bit breaks through. Use support handles if the stall torque is high. The safety standard ISO11148 part 3 recommends using a device to absorb a reaction torque above 10 Nm for pistol grip tools and 4 Nm for straight tools.

    • When using direct-driven screwdrivers or nutrunners:

      Reaction forces depend on the tool settings and joint characteristics. Strength and posture determine the amount of reaction force that an operator can tolerate. Adapt the torque setting to the operator's strength and posture and use a torque arm or reaction bar if the torque is too high.

  • In dusty environments, use a dust extraction system or wear a mouth protection mask.

Operating Instructions

  • Operating

Operating

Make sure that the tool is in correct working order and that the controller is correctly programmed to avoid unexpected behaviour from the tool, which may result in operator injury.

Check that the tool is in the correct running direction by looking at the function light situated above the tool handle, by turning the reverse ring (only for ETV/ETD DS or by turning the arm on the trigger knob (only for ETP DS).

The soft-start function facilitates entering the screw head and thread.

The duration of the soft start is adjustable, see the manual for the drive unit.

The tool is equipped with signal lights,

  • Green = OK tightening

  • Yellow = Warning – low torque (not for ES)

  • Red = Warning – high torque

  • Orange = Function indicator (only for SL and DL)

  • Blue = Function indicator (only for SL)

Service

  • Preventing ESD Problems
  • Maintenance Instructions
    • Overhaul
    • Service Recommendations
  • Lubrication Instructions
    • Lubricating Guide
    • Lubrication
  • Repair Instructions
    • Repair

Preventing ESD Problems

The components inside the product and controller are sensitive to electrostatic discharge. To avoid future malfunction, make sure that service and maintenance is carried out in an ESD approved work environment. The figure below shows an example of an appropriate service work station.

Maintenance Instructions

  • Overhaul
  • Service Recommendations

Overhaul

Service must only be carried out by qualified personnel who have access to the Service instruction and/or have been trained for service on Tensor tools.

The electric motor is a sealed unit and may under no circumstances be opened by anyone else than Atlas Copco Industrial Technique AB!

If you decide that the electric motor is defect or in need of service, return the complete motor unit to Atlas Copco Industrial Technique for replacement.

Motors which have been opened by anyone else than Atlas Copco Industrial Technique will not be serviced.

Overhaul and preventive maintenance is recommended at regular intervals once per year or after maximum 250.000 tightening depending on which occurs sooner. More frequent overhaul may be needed if the machine is used in heavy-duty operations. If the machine not is working properly, it should immediately be taken away for inspection.

When dismantling the tool always use the specially designed service tool 4080 0848 80, (two service tools are required).

Service Recommendations

Preventive maintenance is recommended at regular intervals. See the detailed information on preventive maintenance. If the product is not working properly, take it out of service and inspect it.

If no detailed information about preventive maintenance is included, follow these general guidelines:

  • Clean appropriate parts accurately

  • Replace any defective or worn parts

Lubrication Instructions

  • Lubricating Guide
  • Lubrication

Lubricating Guide

Brand

Cable nut

Gears

Molycote

 

BR2 Plus

CRC

Litium grease No. 3020

 

Brand

Angle gears

General purpose

Molycote

Longterm 2 plus

 

Almagard

 

LE 3751

Lubrication

Planetary gears, needle bearings and ball bearings must be lubricated with soft grease containing molybdenumdisulphide at the regular overhaul of the tool.

 

Repair Instructions

  • Repair

Repair

Repair must only be carried out by qualified authorised personnel. For further information contact your local Atlas Copco sales representative.

Troubleshooting

  • If the Tool Becomes Very Hot
  • Power Focus 600/6000

If the Tool Becomes Very Hot

With proper adjustment the tool can handle any normal line jobs that an operator sustains. What can cause overheating are combinations of some factors: torque above rated, too low speed, too long ramp time (motor has to give high torque for a long time), very high prevailing torque, very soft joints, short cycle time. To correct, look over speed, ramp time, tightening strategy. One stage and Ergoramp are most heat conserving when applicable. Please refer to the User Guide of your POWER FOCUS. If the above corrections are not enough, choose a tool of the next higher capacity.

Power Focus 600/6000

Is the unit switched on? Check the earth fault circuit breaker behind the front door. Should it have tripped, make sure to find the primary fault before resuming operation. Check that the wiring on the remote start connector is correct. For further information see 9836 4954/9836 7446.

 

Recycling

  • Environmental Regulations

Environmental Regulations

When a product has served its purpose it has to be recycled properly. Dismantle the product and recycle the components in accordance with local legislation.

Batteries shall be taken care of by your national battery recovery organization.

ETD SL21-04-SF | A2400001 - | 8433220104

Published: 2021-03-08

© Atlas Copco Industrial Technique AB, 2021 | Legal Notice