Relays
Relays Relay out
There are 8 relayoutputs. Normally open or normally closed depending on the connection.
Connector
24-pin detachable screw terminal. Mating connector Phoenix MCVR 1.5/12-ST.3.81 or compatible.
Function
Two way dry contact relays. Isolated outputs. Logical function is set in the configuration of the PowerFocus or DS-drive.
Electrical data
Max 50VDC/AC. Switching load: min 1mA, max 500 mA resistive load.
Pos. No. | Function |
---|---|
1 | Relay 5 normally open |
2 | Relay 5 common |
3 | Relay 5 normally closed |
4 | Relay 6 normally open |
5 | Relay 6 common |
6 | Relay 6 normally closed |
7 | Relay 7 normally open |
8 | Relay 7 common |
9 | Relay 7 normally closed |
10 | Relay 8 normally open |
11 | Relay 8 common |
12 | Relay 8 normally closed |
13 | 24V external output |
14 | 24V external output |
| |
25 | Relay 5 normally open |
26 | Relay 5 common |
27 | Relay 5 normally closed |
28 | Relay 5 normally open |
29 | Relay 5 common |
30 | Relay 5 normally closed |
31 | Relay 5 normally open |
32 | Relay 5 common |
33 | Relay 5 normally closed |
34 | Relay 5 normally open |
35 | Relay 5 common |
36 | Relay 5 normally closed |
37 | 24V external ground |
38 | 24V external ground |
Screw terminal

External output