Product Information

  • General Information
    • Safety Signal Words
    • Warranty
    • Website
    • ServAid
    • Safety Data Sheets MSDS/SDS
    • Product Safety Video for Nutrunners
    • Country of Origin
    • Dimensional Drawings
  • Overview
    • Technical Product Data
  • Service Overview
    • Service Recommendations
    • Preventive maintenance

General Information

WARNING

Risk of Property Damage or Severe Injury

Ensure that you read, understand and follow all instructions before operating the tool. Failure to follow all the instructions may result in electric shock, fire, property damage and/or severe bodily injury.

  • Read all Safety Information delivered together with the different parts of the system.

  • Read all Product Instructions for installation, operation and maintenance of the different parts of the system.

  • Read all locally legislated safety regulations regarding the system and parts thereof.

  • Save all Safety Information and instructions for future reference.

In this Section
  • Safety Signal Words
  • Warranty
  • Website
  • ServAid
  • Safety Data Sheets MSDS/SDS
  • Product Safety Video for Nutrunners
  • Country of Origin
  • Dimensional Drawings

Safety Signal Words

The safety signal words Danger, Warning, Caution, and Notice have the following meanings:

DANGER

DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.

WARNING

WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.

CAUTION

CAUTION, used with the safety alert symbol, indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

NOTICE

NOTICE is used to address practices not related to personal injury.

Warranty

  • Product warranty will expire 12 months after the product is first taken into use, but will in any case expire at the latest 13 months after delivery.

  • Normal wear and tear on parts is not included within the warranty.

    • Normal wear and tear is that which requires a part change or other adjustment/overhaul during standard tools maintenance typical for that period (expressed in time, operation hours or otherwise).

  • The product warranty relies on the correct use, maintenance, and repair of the tool and its component parts.

  • Damage to parts that occurs as a result of inadequate maintenance or performed by parties other than Atlas Copco or their Certified Service Partners during the warranty period is not covered by the warranty.

  • To avoid damage or destruction of tool parts, service the tool according to the recommended maintenance schedules and follow the correct instructions.

  • Warranty repairs are only performed in Atlas Copco workshops or by Certified Service Partners.

Atlas Copco offers extended warranty and state of the art preventive maintenance through its ToolCover contracts. For further information contact your local Service representative.

For electrical motors:

  • Warranty will only apply when the electric motor has not been opened.

Website

Information concerning our Products, Accessories, Spare Parts and Published Matters can be found on the Atlas Copco website.

Please visit: www.atlascopco.com.

ServAid

ServAid is a portal that is continuously updated and contains Technical Information, such as:

  • Regulatory and Safety Information

  • Technical Data

  • Installation, Operation and Service Instructions

  • Spare Parts Lists

  • Accessories

  • Dimensional Drawings

Please visit: https://servaid.atlascopco.com.

For further Technical Information, please contact your local Atlas Copco representative.

Safety Data Sheets MSDS/SDS

The Safety Data Sheets describe the chemical products sold by Atlas Copco.

Please consult the Atlas Copco website for more information www.atlascopco.com/sds.

Product Safety Video for Nutrunners

Learn more about safety features on Atlas Copco nutrunners and what measures the operator has to take for a safe operation. Click the link or scan the QR code below to view the video:

https://www.youtube.com/watch?v=FAh6yttvUpw

Country of Origin

For the Country of Origin, please refer to the information on the product label.

Dimensional Drawings

Dimensional Drawings can be found either in the Dimensional Drawings Archive, or on ServAid.

Please visit: http://webbox.atlascopco.com/webbox/dimdrw or https://servaid.atlascopco.com.

Overview

  • Technical Product Data

Technical Product Data

Technical Product Data can be found on either ServAid, or the Atlas Copco website.

Please visit: https://servaid.atlascopco.com or www.atlascopco.com.

Service Overview

  • Service Recommendations
  • Preventive maintenance

Service Recommendations

Preventive maintenance is recommended at regular intervals. See the detailed information on preventive maintenance. If the product is not working properly, take it out of service and inspect it.

If no detailed information about preventive maintenance is included, follow these general guidelines:

  • Clean appropriate parts accurately

  • Replace any defective or worn parts

Preventive maintenance

Overhaul and preventive maintenance is recommended at regular intervals once per year or after maximum 250.000 tightening depending on which occurs sooner. More frequent overhaul may be needed, if used at high torque and long tightening times.

Installation

  • Installation Requirements
    • Air Quality
    • Air Lubrication Guide
    • Compressed Air Connection

Installation Requirements

  • Air Quality
  • Air Lubrication Guide
  • Compressed Air Connection

Air Quality

  • For optimum performance and maximum product life we recommend the use of compressed air with a maximum dew point of +10°C (50°F). We also recommend to install an Atlas Copco refrigeration type air dryer.

  • Use a separate air filter which removes solid particles larger than 30 microns and more than 90% of liquid water. Install the filter as close as possible to the product and prior to any other air preparation units to avoid pressure drop.

For impulse/impact tools make sure to use lubricators adjusted for these tools. Regular lubricators will add too much oil and therefore decrease the tool performance due to too much oil in the motor.

Make sure that the hose and couplings are clean and free from dust before connecting to the tool.

Both lubricated and lubrication free products will benefit from a small quantity of oil supplied from a lubricator.

Air Lubrication Guide

Brand

Air lubrication

Atlas Copco

Optimizer (1 liter) 9090 0000 04

Q8

Chopin 46

Shell

Shell Air Tool Oil S2 A 320

Compressed Air Connection

WARNING

Risk of severe injury

Air under pressure can cause injury.

  • Always shut off the air supply when not in use or before any adjustments.

  • Drain the hose of air pressure and disconnect the tool from air supply when not in use or before any adjustments.

  • Always use the correct hose size and air pressure for the tool.

WARNING

Compressed Air

High air pressure can cause severe damage and bodily injury.

  • Do not exceed maximum air pressure.

  • Make sure that there are no damaged or loose hoses or fittings.

For correct air pressure and hose size, see the Technical Product Data on - https://servaid.atlascopco.com or www.atlascopco.com.

Make sure that the hose and couplings are clean and free from dust before connecting to the tool.

Operation

  • Ergonomic Guidelines
  • Operating Instructions
    • Tightening Torque
      • Verification of Tightening Torque
    • Air Pressure Monitoring, RE-Signal S1

Ergonomic Guidelines

Consider your workstation as you read through this list of general ergonomic guidelines to identify areas for improvement in posture, component placement, or work environment.

  • Take frequent breaks and change work positions frequently.

  • Adapt the workstation area to your needs and the work task.

    • Adjust for a convenient reach range by determining where parts and tools need to be located to avoid static load.

    • Use workstation equipment such as tables and chairs appropriate for the work task.

  • Avoid work positions above shoulder level or with static holding during assembly operations.

    • When working above shoulder level, reduce the load on the static muscles by lowering the weight of the tool, using for example torque arms, hose reels or weight balancers. You can also reduce the load on the static muscles by holding the tool close to the body.

    • Take frequent breaks.

    • Avoid extreme arm or wrist postures, particularly during operations requiring a degree of force.

  • Adjust for a convenient field of vision that requires minimal eye and head movements.

  • Use appropriate lighting for the work task.

  • Select the appropriate tool for the work task.

  • In noisy environments, use ear protection equipment.

  • Use high-quality inserted tools and consumables to minimize exposure to excessive levels of vibration.

  • Minimize exposure to reaction forces.

    • When cutting:

      A cut-off wheel can get stuck if the cut-off wheel is bent or not guided properly. Use the correct flange for the cut-off wheel and avoid bending the cut-off wheel during operation.

    • When drilling:

      The drill might stall when the drill bit breaks through. Use support handles if the stall torque is high. The safety standard ISO11148 part 3 recommends using a device to absorb a reaction torque above 10 Nm for pistol grip tools and 4 Nm for straight tools.

    • When using direct-driven screwdrivers or nutrunners:

      Reaction forces depend on the tool settings and joint characteristics. Strength and posture determine the amount of reaction force that an operator can tolerate. Adapt the torque setting to the operator's strength and posture and use a torque arm or reaction bar if the torque is too high.

  • In dusty environments, use a dust extraction system or wear a mouth protection mask.

Operating Instructions

  • Tightening Torque
    • Verification of Tightening Torque
  • Air Pressure Monitoring, RE-Signal S1

Tightening Torque

For accurate operation and safety, the tightening torque of the nut runner must be set correctly in relation to the screw joint. Check the tightening torque given to the joint in question.

The tightening torque is adjusted by altering the tension of the clutch spring. Turn the protection ring until the hole in the clutch housing is free. Then turn the out going spindle until you can see the keyhole in the adjustment washer. Turn the adjustment key clockwise to decrease and anticlockwise to increase the torque. After the adjustment, turn the protective ring back again.

In this Section
  • Verification of Tightening Torque

Verification of Tightening Torque

Recommended equipment for verification if tightening torque are an Atlas Copco Torque Analyser plus an appropriately-sized transducer together with the available test joints.

Air Pressure Monitoring, RE-Signal S1

Reporting pneumatic assembly tools provide a pneumatic signal that indicates which part of the tightening cycle the tool has reached, by means of variations in air pressure.

In the RE-Controller box timers are triggered when certain pressure levels are reached.

Pressure level 1 (P1) starts a timer that checks that the tightening cycle is not too short.

Pressure level 2 (P2) starts a timer that checks the time taken from when the clutch has been released to when the operator releases the trigger to ensure that it is not too short.

The controller measures the differential pressure over the motor.

It should be noted that the system does not measure torque! Regular check of installed torque/torque output of the tool must be done separately.

The RE-Controller checks the air-line pressure. One of the most common problems in air-line systems is pressure variations. If the pressure drops too much the tool might stall and/or the torque will not be correct. The RE-Controller will give a signal if the pressure drops too much.

The RE-Controller alerts the operator when it detects:

  • Missed fasteners

  • Premature tool shut-off

  • Stripped threads

  • Cross-threading

  • Rehits

  • Drop in air supply

The air pressure inside the tool is measured through a small hose (see Optional accessories - Kit RE-Signal) and converted into a digital signal. This signal is processed in the RE-Controller. The RE-Controller gives instant visual and audio feedback to the operator on whether the tightening was OK or not OK.

For further information, please see leaflet 9833 1358 01.

Service

  • Maintenance Instructions
    • Service Recommendations
    • Preventive Maintenance
      • Preventive maintenance
    • Tightening of Threaded Connections
      • Example
    • Service instructions
      • Instructions for reversing
        • Clockwise rotation
        • Counterclockwise rotation
      • Instructions for Vane Motors
        • Dismantling
        • Inspection of Motor Parts
        • Assembling - According to Bäckströms Method
      • Testing of tightening torque
        • Torque and angle testing instrument
        • Testjoint and Transducer
      • Service instructions
      • Cleaning
      • Inspection
  • Lubrication Instructions
    • Rust Protection and Cleaning
    • Lubrication Guide
    • Lubrication of motor parts
    • Lubrication of gears in clutch casing
    • For Maximum Performance
  • Dismantling/Assembling Instructions
    • Dismantling of Motor
    • Assembly of Motor

Maintenance Instructions

  • Service Recommendations
  • Preventive Maintenance
    • Preventive maintenance
  • Tightening of Threaded Connections
    • Example
  • Service instructions
    • Instructions for reversing
      • Clockwise rotation
      • Counterclockwise rotation
    • Instructions for Vane Motors
      • Dismantling
      • Inspection of Motor Parts
      • Assembling - According to Bäckströms Method
    • Testing of tightening torque
      • Torque and angle testing instrument
      • Testjoint and Transducer
    • Service instructions
    • Cleaning
    • Inspection

Service Recommendations

Preventive maintenance is recommended at regular intervals. See the detailed information on preventive maintenance. If the product is not working properly, take it out of service and inspect it.

If no detailed information about preventive maintenance is included, follow these general guidelines:

  • Clean appropriate parts accurately

  • Replace any defective or worn parts

Preventive Maintenance

  • Preventive maintenance

Preventive maintenance

Overhaul and preventive maintenance is recommended at regular intervals once per year or after maximum 250.000 tightening depending on which occurs sooner. More frequent overhaul may be needed, if used at high torque and long tightening times.

Tightening of Threaded Connections

The tightening torques indicated in the exploded views list in ServAid (see Spare parts section in https://servaid.atlascopco.com) are established to achieve the correct clamping force and prevent the parts from coming loose.

When servicing these parts, they must be able to open up without being destroyed. In special circumstances (depending on application and usage) the parts may however come loose after some time of operation. In such cases the torque can be increased by 10-20%. If necessary, a low or medium threadlocking fluid can also be applied.

In this Section
  • Example

Example

Service instructions

  • Instructions for reversing
    • Clockwise rotation
    • Counterclockwise rotation
  • Instructions for Vane Motors
    • Dismantling
    • Inspection of Motor Parts
    • Assembling - According to Bäckströms Method
  • Testing of tightening torque
    • Torque and angle testing instrument
    • Testjoint and Transducer
  • Service instructions
  • Cleaning
  • Inspection

Instructions for reversing

Changing the rotation direction of the tool can only be done when the lever is completely released.

In this Section
  • Clockwise rotation
  • Counterclockwise rotation

Clockwise rotation

Grip the gear shift ring and pull it backwards (A). Turn it counterclockwise until stop (B). Release the shift ring and make sure that the shift ring returns to its most forward position.

Only the arrows indicating clockwise rotation should be visible (D).

Counterclockwise rotation

Grip the gear shift ring and pull it backwards (A). Turn it clockwise until stop (C). Release the shift ring and make sure that the shift ring returns to its most forward position.

Only the arrows indicating counterclockwise rotation should be visible (E).

Instructions for Vane Motors

  • Dismantling
  • Inspection of Motor Parts
  • Assembling - According to Bäckströms Method

Dismantling

Service tools are also included in the Basic Service Tools set. For further information see ordering No. 9835 5485 00

Dismantling tool Mandrel A

Ordering No.

Ø D

Ø C

4080 0182 01

7

3.5

4080 0182 02

8

4.5

4080 0182 03

9

5.5

4080 0182 04

10

6.5

4080 0182 05

13

8.5

4080 0182 06

16

10.5

4080 0182 07

19

12.5

4080 0182 08

22

15.5

4080 0182 09

24

17.5

4080 0182 10

26

20.5

4080 0182 11

30

25.5

4080 0182 12

35

30.5

4080 0182 13

40

35.5

4080 0182 14

47

40.5

Inspection of Motor Parts

Assembling - According to Bäckströms Method

E: Ball bearing

Service tools are also included in the Basic Service Tools set. For further information see ordering No. 9835 5485 00

Dismantling tool Mandrel B

Ordering No.

Ø D

Ø C

4080 0567 04

12.5

5.2

4080 0567 11

14.5

6.5

4080 0567 01

15.5

5.2

4080 0567 05

18.5

6.2

4080 0567 02

18.5

8.2

4080 0567 06

21.5

7.5

4080 0567 03

21.5

8.2

4080 0567 07

25.5

10.5

4080 0567 08

27.5

12.5

4080 0567 09

31.5

15.5

4080 0567 10

34.5

18.5

Testing of tightening torque

  • Torque and angle testing instrument
  • Testjoint and Transducer

Torque and angle testing instrument

ACTA* 3000/ 4000. For further informatiom, please see our main catalogue or separate leaflet.

Testjoint and Transducer

Select testjoint and transducers according to maximum torque of your tool

Service instructions

Overhaul and preventive maintenance is recommended at regular intervals once per year or after maximum 250.000 tightening depending on which occurs sooner. More frequent overhaul may be needed, if used at high torque and long tightening times. If the machine is not working properly, it should immediately be taken away for inspection.

The strainer at the air inlet and the exhaust silencer should be cleaned frequently or replaced in order to prevent clogging, which decreases the capacity.

At the overhauls, all parts should be cleaned accurately and defective or worn parts (i.e. O-rings, vanes) should be replaced.

Cleaning

Clean all parts thoroughly in white spirit or similar cleaning agent. To prevent clogging and decreased power, it could be necessary to clean the strainer (if used) and the exhaust filter between the overhauls.

Inspection

After the cleaning, inspect all parts. Damaged and worn parts should be replaced.

Lubrication Instructions

  • Rust Protection and Cleaning
  • Lubrication Guide
  • Lubrication of motor parts
  • Lubrication of gears in clutch casing
  • For Maximum Performance

Rust Protection and Cleaning

Water in the compressed air can cause rust. To prevent rust we strongly recommend to install an air dryer.

Water and particles can cause sticking of vanes and valves. This can be prevented by installing an air filter close to the product to avoid pressure drop.

Before longer stand stills always protect your tool by adding a few drops of oil into the air inlet. Run the tool for 5–10 seconds and absorb any access oil at the air outlet in a cloth.

Lubrication Guide

Brand

General purpose, Bearings and Gears*

BP

Energrease LS-EP2

Castrol

OBEEn UF 1

Esso

Beacon EP2

Q8

Rembrandt EP2

Mobil

Mobilegrease XHP 222 NLG 2

Klüber Lub.

Klübersynth UH 1 14-151

Texaco

Multifak EP2

Molykote

BR2 Plus

* Not for angle gears.

Brand

Angle gears

Molykote

Longterm 2 Plus

Lubrication of motor parts

  • No grease is needed for protected Ball bearings.

  • Apply a thin layer of oil where needed.

Lubrication of gears in clutch casing

For Maximum Performance

At tough working conditions – soft joints and max. setting – lubrication of the air is recommended.

With extreme dry air the service life of vanes and machine performance might be reduced. A daily supply of 0.1 – 0.2 ml oil into the machine inlet will improve the machine performance. Alternatively consider an automatic lubricator device, Atlas Copco oil fog lubricator DIM, or single point lubricator DOS, which will improve the machine performance.

Dismantling/Assembling Instructions

  • Dismantling of Motor
  • Assembly of Motor

Dismantling of Motor

Assembly of Motor

Recycling

  • Environmental Regulations
  • Recycling Information

Environmental Regulations

When a product has served its purpose it has to be recycled properly. Dismantle the product and recycle the components in accordance with local legislation.

Batteries shall be taken care of by your national battery recovery organization.

Recycling Information

Position

Part

Recycle as

1

Angle head

Metal, Steel

2

Cover nut

Metal, Aluminum

3

Clutch

Metal, Steel

4

Lock nut

Metal, Steel

5

Cover

Metal, Aluminum

6

Gear casing

Metal, Aluminum

7

Gears

Metal, Steel

8

Gear shift ring

Metal, Aluminum

9

Vane motor

Metal, Steel*

10

Pin

Metal, Steel

11

Spring

Metal, Steel

12

Motor housing

Metal, Aluminum

Rubber

13

Valve pin

Metal, Steel

14

Pin

Metal, Steel

15

Lever

Metal, Steel

16

Adapter

Metal, Steel

17

Distributor

Metal, Steel

18

Adapter

Metal, Steel

LTV39-2 R200-HAD | A3520001 - | 8431063283